Files
vuln-nvd/data/2025/CVE-2025-4386.json
T

2 lines
2.2 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"MyCareLink Patient Monitor 24950","vendor":"Medtronic","versions":[{"lessThan":"February 25, 2026","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"MyCareLink Patient Monitor 24952","vendor":"Medtronic","versions":[{"lessThan":"February 25, 2026","status":"affected","version":"0","versionType":"custom"}]}],"source":"security@medtronic.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART terminal.​"},{"lang":"es","value":"El Monitor de Paciente Medtronic MyCareLink tiene una interfaz serie interna, que permite a un atacante con acceso físico acceder a una solicitud de inicio de sesión a través de un terminal UART."}],"id":"CVE-2025-4386","lastModified":"2026-10-14T13:10:00.187","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"HIGH","baseScore":6.8,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":0.9,"impactScore":5.9,"source":"security@medtronic.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-4386","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-07T15:43:31.207004Z","version":"2.0.3"}}]},"published":"2026-05-07T16:16:17.287","references":[{"source":"security@medtronic.com","url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-205-01"},{"source":"security@medtronic.com","url":"https://www.medtronic.com/en-us/e/product-security/security-bulletins/mycarelink-patient-monitor-vulnerabilities.html"}],"sourceIdentifier":"security@medtronic.com","vulnStatus":"Awaiting Analysis","weaknesses":[{"description":[{"lang":"en","value":"CWE-1263"}],"source":"security@medtronic.com","type":"Secondary"}]}