{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"ERP-Gateway 12x Digital Input, 6x Digital Relais","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"ERP-Gateway 2x Digital Input, 2x Digital Output","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"ERP-Gateway 2x Digital PoE","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Count 6x Digital","vendor":"Wiesemann & Theis","versions":[{"lessThan":"3.79","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Web-Graph Air Quality","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO 12x Digital Input, 6x Digital Relais","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO 12x Digital Input, 6x Digital Relais","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO 12x Digital Input, 6x Digital Relais","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Analog-In/Out 2x 0/4..20mA PoE","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 12xIn, 12xOut","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 12xIn, 12xOut","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 12xIn, 12xOut","vendor":"Wiesemann & Theis","versions":[{"lessThan":"4.08","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 12xIn, 12xOut, 1xRS232","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 12xIn, 12xOut, 1xRS232","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 2xIn, 2xOut","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 2xIn, 2xOut","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital 2xIn, 2xOut","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-IO Digital Logger 6xIn, 6xOut","vendor":"Wiesemann & Theis","versions":[{"lessThan":"3.70","status":"affected","version":"0","versionType":"semver"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph 2x","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph 8x","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph NTC","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph NTC PoE","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph Pt100 / Pt1000","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph Pt100 / Pt1000 PoE","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermograph Relais","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermo-Hygrobarograph","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]},{"defaultStatus":"unaffected","product":"Web-Thermo-Hygrograph","vendor":"Wiesemann & Theis","versions":[{"status":"affected","version":"all"}]}],"source":"info@cert.vde.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact."},{"lang":"es","value":"Un atacante remoto con pocos privilegios puede ejecutar scripts web o HTML arbitrarios a través de un payload manipulado inyectado en varios campos de la página web de configuración con un impacto limitado."}],"id":"CVE-2025-3020","lastModified":"2026-06-17T09:19:02.180","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.4,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N","version":"3.1"},"exploitabilityScore":2.8,"impactScore":2.5,"source":"info@cert.vde.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-3020","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-05-06T13:52:10.556193Z","version":"2.0.3"}}]},"published":"2025-05-06T08:15:16.397","references":[{"source":"info@cert.vde.com","url":"https://cert.vde.com/en/advisories/VDE-2025-032"}],"sourceIdentifier":"info@cert.vde.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-79"}],"source":"info@cert.vde.com","type":"Secondary"}]}
|