Files
vuln-nvd/data/2025/CVE-2025-1790.json
T

2 lines
2.9 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","platforms":["Windows"],"product":"Genetec Sipelia","vendor":"Genetec Inc.","versions":[{"status":"affected","version":"<2.14.271","versionType":"semver"},{"status":"unaffected","version":">=2.14.271","versionType":"semver"}]}],"source":"security@genetec.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Local privilege escalation in Genetec Sipelia Plugin. An authenticated low-privileged Windows user could exploit this vulnerability to gain elevated privileges on the affected system."},{"lang":"es","value":"Escalada de privilegios local en el plugin Genetec Sipelia. Un usuario de Windows autenticado con bajos privilegios podría explotar esta vulnerabilidad para obtener privilegios elevados en el sistema afectado."}],"id":"CVE-2025-1790","lastModified":"2026-06-17T08:39:46.817","metrics":{"cvssMetricV40":[{"cvssData":{"Automatable":"NO","Recovery":"NOT_DEFINED","Safety":"PRESENT","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"LOCAL","availabilityRequirement":"NOT_DEFINED","baseScore":5.8,"baseSeverity":"MEDIUM","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"UNREPORTED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","userInteraction":"NONE","valueDensity":"CONCENTRATED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:U/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:N/R:X/V:C/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"security@genetec.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-1790","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2026-02-13T21:11:34.858558Z","version":"2.0.3"}}]},"published":"2026-02-13T17:16:10.917","references":[{"source":"security@genetec.com","url":"https://techdocs.genetec.com/r/en-US/Security-Updates-for-SipeliaTM-2.14/"}],"sourceIdentifier":"security@genetec.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-250"}],"source":"security@genetec.com","type":"Secondary"}]}