Files
vuln-nvd/data/2025/CVE-2025-0631.json
T

2 lines
2.8 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"PowerFlex 755","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"<=16.002.279"}]}],"source":"PSIRT@rockwellautomation.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text."},{"lang":"es","value":"Existe una vulnerabilidad de exposición de credenciales en el producto y la versión mencionados anteriormente. La vulnerabilidad se debe al uso de HTTP, lo que hace que las credenciales se envíen en texto plano."}],"id":"CVE-2025-0631","lastModified":"2026-06-17T08:26:52.227","metrics":{"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":8.7,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"PSIRT@rockwellautomation.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-0631","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-01-28T18:57:46.274914Z","version":"2.0.3"}}]},"published":"2025-01-28T19:15:14.270","references":[{"source":"PSIRT@rockwellautomation.com","url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1717.html"}],"sourceIdentifier":"PSIRT@rockwellautomation.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-319"}],"source":"PSIRT@rockwellautomation.com","type":"Secondary"}]}