2 lines
4.4 KiB
JSON
2 lines
4.4 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"LabVIEW","vendor":"NI","versions":[{"lessThanOrEqual":"24.1","status":"affected","version":"0","versionType":"semver"}]}],"source":"security@ni.com"},{"affectedData":[{"cpes":["cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"labview","vendor":"ni","versions":[{"lessThanOrEqual":"24.1","status":"affected","version":"0","versionType":"semver"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:ni:labview:*:*:*:*:*:*:*:*","matchCriteriaId":"E9BBCA76-7B4C-4CC5-A782-489CA4223C04","versionEndIncluding":"2020","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2021:-:*:*:*:*:*:*","matchCriteriaId":"9F184512-5D11-47F4-8555-EA6FF93C106F","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2021:sp1:*:*:*:*:*:*","matchCriteriaId":"BF28259A-30A6-4BB1-B262-A006AB74AFFA","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2022:q1:*:*:*:*:*:*","matchCriteriaId":"4D12D6CF-802F-47BA-ADF9-9E52C071BD7F","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2022:q3:*:*:*:*:*:*","matchCriteriaId":"340F61E5-D1ED-4C29-A894-8BC5C5B90ACE","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2023:q1:*:*:*:*:*:*","matchCriteriaId":"D7DD2022-CFB7-4F38-B459-C1AFB55B5B68","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2023:q3:*:*:*:*:*:*","matchCriteriaId":"18AB0B07-72FE-4861-B69D-AD2E87C5382E","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2023:q3_patch2:*:*:*:*:*:*","matchCriteriaId":"044C4B51-C641-41F2-ACA0-834C99D63285","vulnerable":true},{"criteria":"cpe:2.3:a:ni:labview:2024:q1:*:*:*:*:*:*","matchCriteriaId":"7753CCDF-BAF8-4F91-B85B-EBB2B88F6F30","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions."},{"lang":"es","value":"Una lectura fuera de los límites debido a una verificación de límites faltantes en LabVIEW puede revelar información o resultar en la ejecución de código arbitrario. La explotación exitosa requiere que un atacante proporcione al usuario un VI especialmente manipulado. Esta vulnerabilidad afecta a LabVIEW 2024 Q1 y versiones anteriores."}],"id":"CVE-2024-4079","lastModified":"2026-06-17T08:01:04.020","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"security@ni.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-4079","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-07-23T14:10:10.492631Z","version":"2.0.3"}}]},"published":"2024-07-23T14:15:14.353","references":[{"source":"security@ni.com","tags":["Vendor Advisory"],"url":"https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/out-of-bounds-read-due-to-missing-bounds-check-in-labview.html"}],"sourceIdentifier":"security@ni.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-125"}],"source":"security@ni.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-125"}],"source":"nvd@nist.gov","type":"Primary"}]}
|