2 lines
10 KiB
JSON
2 lines
10 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Scene Viewer","vendor":"B&R Industrial Automation","versions":[{"lessThan":"4.4.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Automation Runtime","vendor":"B&R Industrial Automation","versions":[{"lessThan":"J4.93","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"mapp Vision","vendor":"B&R Industrial Automation","versions":[{"lessThan":"5.26.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"mapp View","vendor":"B&R Industrial Automation","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"mapp Cockpit","vendor":"B&R Industrial Automation","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"mapp Safety","vendor":"B&R Industrial Automation","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"VC4","vendor":"B&R Industrial Automation","versions":[{"lessThan":"4.73.2","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"APROL","vendor":"B&R Industrial Automation","versions":[{"lessThan":"4.4-01","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"CAN Driver","vendor":"B&R Industrial Automation","versions":[{"lessThan":"1.1.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"CAN Driver CC770","vendor":"B&R Industrial Automation","versions":[{"lessThan":"3.3.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"CAN Driver SJA1000","vendor":"B&R Industrial Automation","versions":[{"lessThan":"1.3.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Tou0ch Lock","vendor":"B&R Industrial Automation","versions":[{"lessThan":"2.1.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"B&R Single-Touch Driver","vendor":"B&R Industrial Automation","versions":[{"lessThan":"2.0.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Serial User Mode Touch Driver","vendor":"B&R Industrial Automation","versions":[{"lessThan":"1.7.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Windows Settings Changer (LTSC)","vendor":"B&R Industrial Automation","versions":[{"lessThan":"3.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Windows Settings Changer (2019 LTSC)","vendor":"B&R Industrial Automation","versions":[{"lessThan":"2.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Windows 10 Recovery Solution","vendor":"B&R Industrial Automation","versions":[{"lessThan":"3.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ADI driver universal","vendor":"B&R Industrial Automation","versions":[{"lessThan":"3.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ADI Development Kit","vendor":"B&R Industrial Automation","versions":[{"lessThan":"5.5.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"ADI .NET SDK","vendor":"B&R Industrial Automation","versions":[{"lessThan":"4.1.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"SRAM driver","vendor":"B&R Industrial Automation","versions":[{"lessThan":"1.2.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"HMI Service Center","vendor":"B&R Industrial Automation","versions":[{"lessThan":"3.1.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"HMI Service Center Maintenance","vendor":"B&R Industrial Automation","versions":[{"lessThan":"2.1.0","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Windows 10 IoT Enterprise 2019 LTSC","vendor":"B&R Industrial Automation","versions":[{"lessThanOrEqual":"1.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"KCF Editor","vendor":"B&R Industrial Automation","versions":[{"lessThan":"1.1.0","status":"affected","version":"0","versionType":"custom"}]}],"source":"cybersecurity@ch.abb.com"},{"affectedData":[{"cpes":["cpe:2.3:a:br-automation:scene_viewer:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"scene_viewer","vendor":"br-automation","versions":[{"lessThan":"4.4.0","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:br-automation:automation_runtime:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"automation_runtime","vendor":"br-automation","versions":[{"lessThan":"j4.93","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:br-automation:mapp_vision:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"mapp_vision","vendor":"br-automation","versions":[{"lessThan":"5.26.1","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:br-automation:mapp_view:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"mapp_view","vendor":"br-automation","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:br-automation:mapp_cockpit:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"mapp_cockpit","vendor":"br-automation","versions":[{"lessThan":"5.24.2","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:br-automation:vc4:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"vc4","vendor":"br-automation","versions":[{"lessThan":"4.73.2","status":"affected","version":"0","versionType":"custom"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"cveTags":[],"descriptions":[{"lang":"en","value":"An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0."},{"lang":"es","value":"Un atacante local autenticado que aprovechara con éxito esta vulnerabilidad podría insertar y ejecutar código arbitrario utilizando software legítimo de B&R. Una vulnerabilidad de elemento de ruta de búsqueda no controlada en B&R Industrial Automation Scene Viewer, B&R Industrial Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4 podría permitir una autenticación atacante local ejecute código malicioso colocando archivos especialmente manipulados en la ruta de búsqueda de carga. Este problema afecta a Scene Viewer: antes de 4.4.0; Automation Runtime: antes de J4.93; mapp Vision: antes de 5.26.1; mapp View: antes de 5.24.2; Cockpit mapp: antes de 5.24.2; mapp Safety: antes de 5.24.2; VC4: antes de 4.73.2."}],"id":"CVE-2024-2637","lastModified":"2026-06-17T07:24:56.563","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":0.6,"impactScore":6.0,"source":"cybersecurity@ch.abb.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2637","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-05-14T19:33:12.195778Z","version":"2.0.3"}}]},"published":"2024-05-14T19:15:10.230","references":[{"source":"cybersecurity@ch.abb.com","url":"https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://www.br-automation.com/fileadmin/SA24P005_Insecure_Loading_of_Code-c7d9e49c.pdf"}],"sourceIdentifier":"cybersecurity@ch.abb.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-427"}],"source":"cybersecurity@ch.abb.com","type":"Secondary"}]}
|