{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"RTU500 series CMU firmware","vendor":"Hitachi Energy","versions":[{"lessThanOrEqual":"13.2.7","status":"affected","version":"13.2.1","versionType":"custom"},{"lessThanOrEqual":"13.4.4","status":"affected","version":"13.4.1","versionType":"custom"},{"lessThanOrEqual":"13.5.3","status":"affected","version":"13.5.1","versionType":"custom"}]}],"source":"cybersecurity@hitachienergy.com"},{"affectedData":[{"cpes":["cpe:2.3:o:hitachienergy:rtu500_firmware:13.2.1.0:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"rtu500_firmware","vendor":"hitachienergy","versions":[{"lessThanOrEqual":"13.2.7.0","status":"affected","version":"13.2.1.0","versionType":"custom"}]},{"cpes":["cpe:2.3:o:hitachienergy:rtu500_firmware:13.4.1.0:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"rtu500_firmware","vendor":"hitachienergy","versions":[{"lessThanOrEqual":"13.4.4.0","status":"affected","version":"13.4.1.0","versionType":"custom"}]},{"cpes":["cpe:2.3:o:hitachienergy:rtu500_firmware:13.5.1.0:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"rtu500_firmware","vendor":"hitachienergy","versions":[{"lessThanOrEqual":"13.5.3.0","status":"affected","version":"13.5.1.0","versionType":"custom"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update, \n\nif secure update feature was not enabled on all\nCMUs of a RTU500. If a\nmalicious actor successfully exploits this vulnerability, they\ncould use it to update the RTU500 with unsigned firmware."},{"lang":"es","value":"Existe una vulnerabilidad en el RTU500 que permite a los usuarios autenticados y autorizados omitir la actualización segura. Si un actor malintencionado aprovecha con éxito esta vulnerabilidad, podría usarla para actualizar el RTU500 con firmware sin firmar."}],"id":"CVE-2024-2617","lastModified":"2026-06-17T07:24:54.053","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.2,"impactScore":5.9,"source":"cybersecurity@hitachienergy.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2617","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-04-30T16:11:48.392692Z","version":"2.0.3"}}]},"published":"2024-04-30T13:15:47.200","references":[{"source":"cybersecurity@hitachienergy.com","url":"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000199&languageCode=en&Preview=true"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000199&languageCode=en&Preview=true"}],"sourceIdentifier":"cybersecurity@hitachienergy.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-358"}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary"}]}