2 lines
3.3 KiB
JSON
2 lines
3.3 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"FoxRTU Station","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to v9.3.0"}]}],"source":"cybersecurity@se.com"},{"affectedData":[{"cpes":["cpe:2.3:a:schneider-electric:foxrtu_station:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"foxrtu_station","vendor":"schneider-electric","versions":[{"lessThan":"9.3.0","status":"affected","version":"0","versionType":"custom"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:schneider-electric:foxrtu_station:*:*:*:*:*:*:*:*","matchCriteriaId":"0C54753D-F3B9-4ED1-A8EF-F6C66561DD9E","versionEndExcluding":"9.3.0","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path\nTraversal') vulnerability exists that could result in remote code execution when an authenticated\nuser executes a saved project file that has been tampered by a malicious actor."},{"lang":"es","value":"CWE-22: Existe una vulnerabilidad de limitación inadecuada de un nombre de ruta a un directorio restringido (\"Path Traversal\") que podría provocar la ejecución remota de código cuando un usuario autenticado ejecuta un archivo de proyecto guardado que ha sido manipulado por un actor malintencionado."}],"id":"CVE-2024-2602","lastModified":"2026-06-17T07:24:51.887","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.3,"impactScore":5.9,"source":"cybersecurity@se.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2602","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-07-11T20:16:22.283836Z","version":"2.0.3"}}]},"published":"2024-07-11T09:15:03.030","references":[{"source":"cybersecurity@se.com","tags":["Vendor Advisory"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-03.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-03.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-22"}],"source":"cybersecurity@se.com","type":"Secondary"}]}
|