2 lines
3.1 KiB
JSON
2 lines
3.1 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"PowerFlex® 527","vendor":"Rockwell Automation ","versions":[{"status":"affected","version":" v2.001.x <"}]}],"source":"PSIRT@rockwellautomation.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:powerflex_527_ac_drives_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"E82898F9-5FA5-428C-AEDA-20E7CD6C229D","versionStartIncluding":"2.001","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:powerflex_527_ac_drives:-:*:*:*:*:*:*:*","matchCriteriaId":"7CDCC60A-0792-4CE4-B73A-07BD1368AC83","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 527 due to improper input validation in the device. If exploited, the web server will crash and need a manual restart to recover it.\n\n"},{"lang":"es","value":"Existe una vulnerabilidad de denegación de servicio en Rockwell Automation PowerFlex® 527 debido a una validación de entrada incorrecta en el dispositivo. Si se explota, el servidor web fallará y será necesario reiniciarlo manualmente para recuperarlo."}],"id":"CVE-2024-2425","lastModified":"2026-06-17T07:24:30.683","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2425","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2024-03-28T18:27:55.373294Z","version":"2.0.3"}}]},"published":"2024-03-25T21:15:47.273","references":[{"source":"PSIRT@rockwellautomation.com","tags":["Vendor Advisory"],"url":"https://https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html"}],"sourceIdentifier":"PSIRT@rockwellautomation.com","vulnStatus":"Analyzed","weaknesses":[{"description":[{"lang":"en","value":"CWE-20"}],"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"description":[{"lang":"en","value":"NVD-CWE-noinfo"}],"source":"nvd@nist.gov","type":"Primary"}]}
|