Files
vuln-nvd/data/2024/CVE-2024-2229.json
T

2 lines
2.5 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"EcoStruxure Power Design - Ecodial","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All Versions NL"},{"status":"affected","version":"All Versions INT"},{"status":"affected","version":"All Versions FR"}]}],"source":"cybersecurity@se.com"},{"affectedData":[{"cpes":["cpe:2.3:a:schneider-electric:ecostruxure_power_monitoring_expert:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"ecostruxure_power_monitoring_expert","vendor":"schneider-electric","versions":[{"lessThanOrEqual":"*","status":"affected","version":"0","versionType":"custom"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nCWE-502: Deserialization of Untrusted Data vulnerability exists that could cause remote code\nexecution when a malicious project file is loaded into the application by a valid user.\n\n"},{"lang":"es","value":"CWE-502: Existe una vulnerabilidad de deserialización de datos no confiables que podría causar la ejecución remota de código cuando un usuario válido carga un archivo de proyecto malicioso en la aplicación."}],"id":"CVE-2024-2229","lastModified":"2026-06-17T07:23:59.630","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2229","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-03-18T16:27:40.910097Z","version":"2.0.3"}}]},"published":"2024-03-18T16:15:09.580","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-02.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-502"}],"source":"cybersecurity@se.com","type":"Secondary"}]}