2 lines
8.0 KiB
JSON
2 lines
8.0 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Venue","vendor":"GE HealthCare","versions":[{"status":"affected","version":"R1"},{"status":"affected","version":"R2"},{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.2","status":"affected","version":"R4","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Venue Go","vendor":"GE HealthCare","versions":[{"status":"affected","version":"R2"},{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.2","status":"affected","version":"R4","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Venue Fit","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.2","status":"affected","version":"R4","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ e","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"R9.1.4","status":"affected","version":"R7","versionType":"custom"},{"lessThanOrEqual":"R10.1.3","status":"affected","version":"R8","versionType":"custom"},{"lessThanOrEqual":"R11.0.2","status":"affected","version":"R9","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"LOGIQ He","vendor":"GE HealthCare","versions":[{"lessThanOrEqual":"R9.3.1","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid E","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"E95","versionType":"custom"},{"lessThan":"206","status":"affected","version":"E90","versionType":"custom"},{"lessThan":"206","status":"affected","version":"E80","versionType":"custom"},{"lessThanOrEqual":"113.2","status":"affected","version":"E9 113.2","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid S","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"70N","versionType":"custom"},{"lessThan":"206","status":"affected","version":"60N","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid T","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"T8","versionType":"custom"},{"lessThan":"206","status":"affected","version":"T9","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Vivid iq","vendor":"GE HealthCare","versions":[{"lessThan":"206","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Invenia ABUS","vendor":"GE HealthCare","versions":[{"status":"affected","version":"1.2.3"}]},{"defaultStatus":"unaffected","product":"Invenia ABUS 2.0","vendor":"GE HealthCare","versions":[{"lessThan":"2.2.9","status":"affected","version":"0","versionType":"custom"}]}],"source":"171caf72-b841-4e04-a68e-93493aff2b94"},{"affectedData":[{"cpes":["cpe:2.3:o:gehealthcare:venue_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"venue_firmware","vendor":"gehealthcare","versions":[{"status":"affected","version":"R1"},{"status":"affected","version":"R2"},{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.2","status":"affected","version":"R4","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:venue_go_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"venue_go_firmware","vendor":"gehealthcare","versions":[{"status":"affected","version":"R2"},{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.2","status":"affected","version":"R4","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:venue_fit_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"venue_fit_firmware","vendor":"gehealthcare","versions":[{"lessThanOrEqual":"R3.3","status":"affected","version":"R3","versionType":"custom"},{"lessThanOrEqual":"R4.2","status":"affected","version":"R4","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:logiq_e_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"logiq_e_firmware","vendor":"gehealthcare","versions":[{"lessThanOrEqual":"R9.1.4","status":"affected","version":"R7","versionType":"custom"},{"lessThanOrEqual":"R10.1.3","status":"affected","version":"R8","versionType":"custom"},{"lessThanOrEqual":"R11.0.2","status":"affected","version":"R9","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:logiq_he_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"logiq_he_firmware","vendor":"gehealthcare","versions":[{"lessThanOrEqual":"R9.3.1","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:vivid_e_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"vivid_e_firmware","vendor":"gehealthcare","versions":[{"lessThan":"206","status":"affected","version":"E95","versionType":"custom"},{"lessThan":"206","status":"affected","version":"E90","versionType":"custom"},{"lessThan":"206","status":"affected","version":"E80","versionType":"custom"},{"lessThanOrEqual":"113.2","status":"affected","version":"E9 113.2","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:vivid_s_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"vivid_s_firmware","vendor":"gehealthcare","versions":[{"lessThan":"206","status":"affected","version":"70N","versionType":"custom"},{"lessThan":"206","status":"affected","version":"60N","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:vivid_t_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"vivid_t_firmware","vendor":"gehealthcare","versions":[{"lessThan":"206","status":"affected","version":"T8","versionType":"custom"},{"lessThan":"206","status":"affected","version":"T9","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:vivid_iq_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"vivid_iq_firmware","vendor":"gehealthcare","versions":[{"lessThan":"206","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:o:gehealthcare:invenia_abus_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"invenia_abus_firmware","vendor":"gehealthcare","versions":[{"status":"affected","version":"1.2.3"}]},{"cpes":["cpe:2.3:o:gehealthcare:invenia_abus_2.0_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unaffected","product":"invenia_abus_2.0_firmware","vendor":"gehealthcare","versions":[{"lessThan":"2.2.9","status":"affected","version":"0","versionType":"custom"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Elevation of privileges via misconfigured access control list in GE HealthCare ultrasound devices"},{"lang":"es","value":"Elevación de privilegios mediante lista de control de acceso mal configurada en dispositivos de ultrasonido de GE HealthCare"}],"id":"CVE-2024-1486","lastModified":"2026-06-17T07:04:20.850","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"HIGH","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.4,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.4,"impactScore":5.9,"source":"171caf72-b841-4e04-a68e-93493aff2b94","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-1486","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-06-12T14:08:59.014421Z","version":"2.0.3"}}]},"published":"2024-05-14T16:15:57.903","references":[{"source":"171caf72-b841-4e04-a68e-93493aff2b94","url":"https://securityupdate.gehealthcare.com/"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://securityupdate.gehealthcare.com/"}],"sourceIdentifier":"171caf72-b841-4e04-a68e-93493aff2b94","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-732"}],"source":"171caf72-b841-4e04-a68e-93493aff2b94","type":"Secondary"}]}
|