Files
vuln-nvd/data/2024/CVE-2024-0840.json
T

2 lines
3.3 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"UCM Series","vendor":"Grandstream","versions":[{"lessThan":"<1.0.20.52","status":"affected","version":"0","versionType":"custom"}]}],"source":"disclosure@vulncheck.com"},{"affectedData":[{"cpes":["cpe:2.3:a:grandstream:ucm6202_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"ucm6202_firmware","vendor":"grandstream","versions":[{"lessThan":"1.0.20.52","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:grandstream:ucm6204_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"ucm6204_firmware","vendor":"grandstream","versions":[{"lessThan":"1.0.20.52","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:grandstream:ucm6208_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"ucm6208_firmware","vendor":"grandstream","versions":[{"lessThan":"1.0.20.52","status":"affected","version":"0","versionType":"custom"}]},{"cpes":["cpe:2.3:a:grandstream:ucm6510_firmware:*:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"ucm6510_firmware","vendor":"grandstream","versions":[{"lessThan":"1.0.20.52","status":"affected","version":"0","versionType":"custom"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"cveTags":[],"descriptions":[{"lang":"en","value":"The Grandstream UCM Series IP PBX before firmware version 1.0.20.52 is affected by a parameter injection vulnerability in the HTTP interface. A remote and authenticated attacker can execute arbitrary code by sending a crafted HTTP request. Authentication may be possible using a default user and password. Affected models are the UCM6202, UCM6204, UCM6208, and UCM6510.\n"},{"lang":"es","value":"La central IP Grandstream UCM Series anterior a la versión de firmware 1.0.20.52 se ve afectada por una vulnerabilidad de inyección de parámetros en la interfaz HTTP. Un atacante remoto y autenticado puede ejecutar código arbitrario enviando una solicitud HTTP manipulada. La autenticación puede ser posible utilizando un usuario y una contraseña predeterminados. Los modelos afectados son UCM6202, UCM6204, UCM6208 y UCM6510."}],"id":"CVE-2024-0840","lastModified":"2026-06-17T06:54:24.887","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":2.8,"impactScore":5.9,"source":"disclosure@vulncheck.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-0840","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-05-01T19:17:53.854809Z","version":"2.0.3"}}]},"published":"2024-04-29T19:15:19.730","references":[{"source":"disclosure@vulncheck.com","url":"https://vulncheck.com/advisories/grand-stream-param-injection"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://vulncheck.com/advisories/grand-stream-param-injection"}],"sourceIdentifier":"disclosure@vulncheck.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-141"}],"source":"disclosure@vulncheck.com","type":"Secondary"}]}