{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"FactoryTalk System Services","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"<= 6.20"}]}],"source":"PSIRT@rockwellautomation.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:rockwellautomation:factorytalk_policy_manager:6.11.0:*:*:*:*:*:*:*","matchCriteriaId":"78D6F03E-E110-4CA7-8883-5CE38FF8E5A0","vulnerable":true},{"criteria":"cpe:2.3:a:rockwellautomation:factorytalk_system_services:6.11.0:*:*:*:*:*:*:*","matchCriteriaId":"46A50229-56B5-4B30-8B4A-6D180D65C2D6","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nRockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.\n\n \n\nImproper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives. This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.\n\n\n"}],"id":"CVE-2023-2638","lastModified":"2026-06-17T05:53:04.403","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.9,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":1.5,"impactScore":4.0,"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"NONE","baseScore":5.0,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:H/A:N","version":"3.1"},"exploitabilityScore":1.3,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2023-2638","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-01-02T20:45:37.679849Z","version":"2.0.3"}}]},"published":"2023-06-13T21:15:09.983","references":[{"source":"PSIRT@rockwellautomation.com","tags":["Permissions Required","Vendor Advisory"],"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Vendor Advisory"],"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1139683"}],"sourceIdentifier":"PSIRT@rockwellautomation.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-287"}],"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-287"}],"source":"nvd@nist.gov","type":"Primary"}]}
|