Files
vuln-nvd/data/2023/CVE-2023-1548.json
T

2 lines
2.7 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"EcoStruxure Control Expert","vendor":"Schneider Electric","versions":[{"status":"affected","version":"V15.1 and above"}]}],"source":"cybersecurity@se.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*","matchCriteriaId":"F00F06FE-58DA-4882-A7E8-0D7E1597026A","versionStartIncluding":"15.1","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nA CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to\nperform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products: EcoStruxure Control Expert (V15.1 and above)"}],"id":"CVE-2023-1548","lastModified":"2026-06-17T05:28:14.093","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":3.6,"source":"cybersecurity@se.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":5.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2023-1548","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-02-05T21:14:14.526696Z","version":"2.0.3"}}]},"published":"2023-04-18T17:15:07.130","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-03.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-03.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-269"}],"source":"cybersecurity@se.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-269"}],"source":"nvd@nist.gov","type":"Secondary"}]}