2 lines
3.9 KiB
JSON
2 lines
3.9 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Illustra Pro Gen 4 Dome","vendor":"Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.","versions":[{"lessThanOrEqual":"Illustra.SS016.05.09.04.0006","status":"affected","version":"0","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Illustra Pro Gen 4 PTZ","vendor":"Sensormatic Electronics, a subsidiary of Johnson Controls, Inc.","versions":[{"lessThanOrEqual":"Illustra.SS010.05.09.04.0022","status":"affected","version":"0","versionType":"custom"}]}],"source":"productsecurity@jci.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:johnsoncontrols:illustra_pro_gen_4_dome_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"4F009944-092A-4E17-8E1E-D4096C0DFB3B","versionEndIncluding":"ss016.05.09.04.0006","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:johnsoncontrols:illustra_pro_gen_4_dome:-:*:*:*:*:*:*:*","matchCriteriaId":"613F554C-1702-418A-91EA-B7F4DE541E7D","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:johnsoncontrols:illustra_pro_gen_4_ptz_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"28735AD3-1977-4D75-99E4-88F55465B643","versionEndIncluding":"ss010.05.09.04.0022","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:johnsoncontrols:illustra_pro_gen_4_ptz:-:*:*:*:*:*:*:*","matchCriteriaId":"8126D886-4123-4756-9D5D-CD030E8BA4FA","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"A debug feature in Sensormatic Electronics Illustra Pro Gen 4 Dome and PTZ cameras allows a user to compromise credentials after a long period of sustained attack."}],"id":"CVE-2023-0954","lastModified":"2026-06-17T05:26:43.710","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"HIGH","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":8.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.6,"impactScore":6.0,"source":"productsecurity@jci.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2023-0954","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2025-01-06T20:20:39.926736Z","version":"2.0.3"}}]},"published":"2023-06-08T21:15:16.183","references":[{"source":"productsecurity@jci.com","tags":["Third Party Advisory","US Government Resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-02"},{"source":"productsecurity@jci.com","tags":["Broken Link"],"url":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","US Government Resource"],"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-23-159-02"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"],"url":"https://www.johnsoncontrols.com/cyber-solutions/security-advisories"}],"sourceIdentifier":"productsecurity@jci.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-489"}],"source":"productsecurity@jci.com","type":"Secondary"},{"description":[{"lang":"en","value":"NVD-CWE-noinfo"}],"source":"nvd@nist.gov","type":"Primary"}]}
|