{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"CompactLogix 5370","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"Compact GuardLogix","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"28","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"ControlLogix 5570","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"ControlLogix 5570 Redundancy","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]},{"defaultStatus":"unaffected","product":"GuardLogix 5570","vendor":"Rockwell Automation","versions":[{"lessThanOrEqual":"33","status":"affected","version":"20","versionType":"Major"}]}],"source":"PSIRT@rockwellautomation.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5370_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"2EFE566E-F923-4357-9A81-CF80C9781460","versionEndIncluding":"33","versionStartIncluding":"20","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:compactlogix_5370:-:*:*:*:*:*:*:*","matchCriteriaId":"E12ADAE3-97B1-48BC-BE69-ED75667C1886","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5370_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"F56AE05D-6230-4540-B57D-F04ADC4AF81E","versionEndIncluding":"33","versionStartIncluding":"28","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:compact_guardlogix_5370:-:*:*:*:*:*:*:*","matchCriteriaId":"6F951670-AF4D-4429-8BC1-79BDEF83B2C3","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"7FFA0CB3-AAF6-4E96-B341-EA9EC76FB1EB","versionEndIncluding":"33","versionStartIncluding":"28","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*","matchCriteriaId":"62414E65-73C7-4172-B7BF-F40A66AFBB90","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:controllogix_5570_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"E926CC52-8EBD-4B0B-86EF-0815028D5422","versionEndIncluding":"33","versionStartIncluding":"20","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:controllogix_5570:-:*:*:*:*:*:*:*","matchCriteriaId":"482E2CD6-D484-486C-92F4-18432D107E30","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:controllogix_5570_redundancy_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"AD1093B1-FA26-4EC5-8B47-34162E2F1645","versionEndIncluding":"33","versionStartIncluding":"20","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:controllogix_5570_redundancy:-:*:*:*:*:*:*:*","matchCriteriaId":"EF7B47C6-086E-45B2-A434-494379C4A0CC","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:guardlogix_5570_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"297151D4-F4AE-4D52-B1BD-82BF13DD4228","versionEndIncluding":"33","versionStartIncluding":"20","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:guardlogix_5570:-:*:*:*:*:*:*:*","matchCriteriaId":"321AE938-192A-4342-8608-ADC81F0B6582","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nA vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). \n\n"},{"lang":"es","value":"Existe una vulnerabilidad en los controladores de Rockwell Automation que permite que una solicitud CIP con formato incorrecto cause una falla mayor no recuperable (MNRF) y una condición de Denegación de Servicio (DoS) (DOS)."}],"id":"CVE-2022-3157","lastModified":"2026-06-17T04:58:58.557","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.6,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":4.0,"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2022-3157","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-04-16T14:31:37.602806Z","version":"2.0.3"}}]},"published":"2022-12-16T21:15:08.797","references":[{"source":"PSIRT@rockwellautomation.com","tags":["Permissions Required","Vendor Advisory"],"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137757"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Vendor Advisory"],"url":"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1137757"}],"sourceIdentifier":"PSIRT@rockwellautomation.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-20"}],"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"description":[{"lang":"en","value":"NVD-CWE-noinfo"}],"source":"nvd@nist.gov","type":"Primary"}]}