Files
vuln-nvd/data/2022/CVE-2022-2988.json
T

2 lines
3.5 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"affected":[{"affectedData":[{"product":"SoMachine HVAC","vendor":"Schneider Electric","versions":[{"lessThan":"V2.1.0","status":"affected","version":"All","versionType":"custom"}]},{"product":"EcoStruxure Machine Expert – HVAC","vendor":"Schneider Electric","versions":[{"lessThan":"V1.4.0","status":"affected","version":"All","versionType":"custom"}]}],"source":"cybersecurity@se.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_machine_expert_-_hvac:*:*:*:*:*:*:*:*","matchCriteriaId":"45F95C91-8A5E-4756-96AE-D5C6E5673107","versionEndExcluding":"1.4.0","vulnerable":true},{"criteria":"cpe:2.3:a:schneider-electric:somachine_hvac:*:*:*:*:*:*:*:*","matchCriteriaId":"04569840-CA17-431D-AB7B-CF62F8BD3FBB","versionEndExcluding":"2.1.0","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0)"},{"lang":"es","value":"Existe una vulnerabilidad CWE-787: escritura fuera de los límites que podría provocar una fuga de información confidencial al acceder a una página web maliciosa desde el software de puesta en marcha. Productos afectados: SoMachine HVAC (versiones anteriores a la V2.1.0), EcoStruxure Machine Expert - HVAC (Versiones anteriores a la V1.4.0)"}],"id":"CVE-2022-2988","lastModified":"2026-06-17T04:42:56.300","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":4.3,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:N","version":"3.1"},"exploitabilityScore":2.8,"impactScore":1.4,"source":"cybersecurity@se.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2022-2988","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-02-05T19:50:42.632868Z","version":"2.0.3"}}]},"published":"2023-01-30T11:15:08.807","references":[{"source":"cybersecurity@se.com","tags":["Release Notes","Vendor Advisory"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Release Notes","Vendor Advisory"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-787"}],"source":"cybersecurity@se.com","type":"Secondary"}]}