2 lines
2.8 KiB
JSON
2 lines
2.8 KiB
JSON
{"affected":[{"affectedData":[{"product":"Remote Compact Controller (RCC) 972","vendor":"Horner Automation","versions":[{"status":"affected","version":"Firmware Version 15.40"}]}],"source":"ics-cert@hq.dhs.gov"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:hornerautomation:rcc972_firmware:15.40:*:*:*:*:*:*:*","matchCriteriaId":"ED633A76-0083-4FCB-8FF3-D0AF4CC58768","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:hornerautomation:rcc972:-:*:*:*:*:*:*:*","matchCriteriaId":"0FF8A08F-B51C-419A-A74D-02F636C19DA9","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Horner Automation’s RCC 972 firmware version 15.40 contains global variables. This could allow an attacker to read out sensitive values and variable keys from the device."},{"lang":"es","value":"La versión 15.40 del firmware RCC 972 de Horner Automation contiene variables globales. Esto podría permitir a un atacante leer valores confidenciales y claves variables del dispositivo."}],"id":"CVE-2022-2642","lastModified":"2026-06-17T04:42:16.123","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"ics-cert@hq.dhs.gov","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2022-2642","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-04-16T15:53:25.203118Z","version":"2.0.3"}}]},"published":"2022-12-02T20:15:13.627","references":[{"source":"ics-cert@hq.dhs.gov","tags":["Patch","Third Party Advisory","US Government Resource"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-335-02"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Third Party Advisory","US Government Resource"],"url":"https://www.cisa.gov/uscert/ics/advisories/icsa-22-335-02"}],"sourceIdentifier":"ics-cert@hq.dhs.gov","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-1108"}],"source":"ics-cert@hq.dhs.gov","type":"Secondary"}]}
|