Files
vuln-nvd/data/2021/CVE-2021-21586.json

2 lines
3.0 KiB
JSON

{"affected":[{"affectedData":[{"product":"Wyse Management Suite","vendor":"Dell","versions":[{"lessThan":"3.3","status":"affected","version":"unspecified","versionType":"custom"}]}],"source":"security_alert@emc.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:dell:wyse_management_suite:*:*:*:*:*:*:*:*","matchCriteriaId":"5AFCC23E-D2F8-44E6-82E5-39E7B08994D9","versionEndIncluding":"3.2","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"Wyse Management Suite versions 3.2 and earlier contain an absolute path traversal vulnerability. A remote authenticated malicious user could exploit this vulnerability in order to read arbitrary files on the system."},{"lang":"es","value":"Wyse Management Suite versiones 3.2 y anteriores contienen una vulnerabilidad de salto de ruta absoluta. Un usuario malicioso no autenticado remoto podría explotar esta vulnerabilidad para leer archivos arbitrarios en el sistema"}],"id":"CVE-2021-21586","lastModified":"2026-06-17T03:35:49.780","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"SINGLE","availabilityImpact":"NONE","baseScore":6.8,"confidentialityImpact":"COMPLETE","integrityImpact":"NONE","vectorString":"AV:N/AC:L/Au:S/C:C/I:N/A:N","version":"2.0"},"exploitabilityScore":8.0,"impactScore":6.9,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":2.2,"impactScore":5.9,"source":"security_alert@emc.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":2.8,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2021-07-15T17:15:08.110","references":[{"source":"security_alert@emc.com","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/kbdoc/000189363"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/kbdoc/000189363"}],"sourceIdentifier":"security_alert@emc.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-36"}],"source":"security_alert@emc.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-22"}],"source":"nvd@nist.gov","type":"Primary"}]}