Files
vuln-nvd/data/2021/CVE-2021-21553.json

2 lines
3.1 KiB
JSON

{"affected":[{"affectedData":[{"product":"PowerScale OneFS","vendor":"Dell","versions":[{"status":"affected","version":"8.1.0-9.1.0"}]}],"source":"security_alert@emc.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:dell:powerscale_onefs:*:*:*:*:*:*:*:*","matchCriteriaId":"F53FE0EF-63C2-4315-B234-BC2CB3E7FDE9","versionEndIncluding":"9.1.0","versionStartIncluding":"8.1.0","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"Dell PowerScale OneFS versions 8.1.0-9.1.0 contain an Incorrect User Management vulnerability.under some specific conditions, this can allow the CompAdmin user to elevate privileges and break out of Compliance mode. This is a critical vulnerability and Dell recommends upgrading at the earliest."},{"lang":"es","value":"Dell PowerScale OneFS versiones 8.1.0-9.1.0, contienen una vulnerabilidad de Administración de Usuarios Incorrecta. En algunas condiciones específicas, esto puede permitir a un usuario de CompAdmin elevar privilegios y salir del modo de Compliance. Esta es una vulnerabilidad crítica y Dell recomienda actualizar lo antes posible"}],"id":"CVE-2021-21553","lastModified":"2026-06-17T03:35:46.060","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"HIGH","cvssData":{"accessComplexity":"LOW","accessVector":"LOCAL","authentication":"NONE","availabilityImpact":"COMPLETE","baseScore":7.2,"confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"exploitabilityScore":3.9,"impactScore":10.0,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.3,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.3,"impactScore":5.9,"source":"security_alert@emc.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":2.0,"impactScore":6.0,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2021-08-03T00:15:08.163","references":[{"source":"security_alert@emc.com","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/kbdoc/000188148"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/kbdoc/000188148"}],"sourceIdentifier":"security_alert@emc.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-286"}],"source":"security_alert@emc.com","type":"Secondary"},{"description":[{"lang":"en","value":"NVD-CWE-Other"}],"source":"nvd@nist.gov","type":"Primary"}]}