Files
vuln-nvd/data/2020/CVE-2020-5837.json
T

2 lines
2.5 KiB
JSON

{"affected":[{"affectedData":[{"product":"Symantec Endpoint Protection","vendor":"n/a","versions":[{"status":"affected","version":"Prior to 14.3"}]}],"source":"secure@symantec.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:symantec:endpoint_protection:*:*:*:*:*:*:*:*","matchCriteriaId":"A9BD7B93-C5F6-4FA1-B450-E54B62F01C5D","versionEndExcluding":"14.3","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"Symantec Endpoint Protection, prior to 14.3, may not respect file permissions when writing to log files that are replaced by symbolic links, which can lead to a potential elevation of privilege."},{"lang":"es","value":"Symantec Endpoint Protection, versiones anteriores a 14.3, puede no respetar los permisos de archivo cuando se escriben en archivos de registro que son reemplazados por enlaces simbólicos, lo que puede conllevar a una potencial elevación de privilegios."}],"id":"CVE-2020-5837","lastModified":"2026-06-17T03:22:18.763","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"LOCAL","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":4.6,"confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","vectorString":"AV:L/AC:L/Au:N/C:P/I:P/A:P","version":"2.0"},"exploitabilityScore":3.9,"impactScore":6.4,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2020-05-11T20:15:12.417","references":[{"source":"secure@symantec.com","tags":["Vendor Advisory"],"url":"https://support.broadcom.com/security-advisory/security-advisory-detail.html?notificationId=SYMSA1762"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://support.broadcom.com/security-advisory/security-advisory-detail.html?notificationId=SYMSA1762"}],"sourceIdentifier":"secure@symantec.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-59"}],"source":"nvd@nist.gov","type":"Primary"}]}