2 lines
4.8 KiB
JSON
2 lines
4.8 KiB
JSON
{"affected":[{"affectedData":[{"modules":["httpd"],"product":"W6","vendor":"Tenda","versions":[{"status":"affected","version":"1.0.0.9(4122)"}]}],"source":"cna@vuldb.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:tenda:w6_firmware:1.0.0.9\\(4122\\):*:*:*:*:*:*:*","matchCriteriaId":"6962A58A-953A-42D2-814D-2AE6DFEDC3B6","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:tenda:w6:-:*:*:*:*:*:*:*","matchCriteriaId":"AF60F314-42D7-4E3A-8200-241FF1A5C517","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda W6 1.0.0.9(4122). It has been rated as critical. Affected by this issue is the function formwrlSSIDset of the file /goform/wifiSSIDset of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-252260. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"es","value":"Se encontró una vulnerabilidad en Tenda W6 1.0.0.9(4122). Ha sido calificada como crítica. La función formwrlSSIDset del archivo /goform/wifiSSIDset del componente httpd es afectada por esta vulnerabilidad. La manipulación del argumento index conduce a un desbordamiento de búfer en la región stack de la memoria. El ataque puede lanzarse de forma remota. La explotación ha sido divulgada al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-252260. NOTA: Se contactó primeramente con proveedor sobre esta divulgación, pero no respondió de ninguna manera."}],"id":"CVE-2024-0995","lastModified":"2026-06-17T06:54:43.550","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"HIGH","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"MULTIPLE","availabilityImpact":"COMPLETE","baseScore":8.3,"confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","vectorString":"AV:N/AC:L/Au:M/C:C/I:C/A:C","version":"2.0"},"exploitabilityScore":6.4,"impactScore":10.0,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"cna@vuldb.com","type":"Secondary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.2,"impactScore":5.9,"source":"cna@vuldb.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-0995","options":[{"exploitation":"poc"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2025-06-02T19:11:50.794914Z","version":"2.0.3"}}]},"published":"2024-01-29T02:15:08.190","references":[{"source":"cna@vuldb.com","tags":["Exploit","Permissions Required","Third Party Advisory"],"url":"https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"},{"source":"cna@vuldb.com","tags":["Permissions Required","Third Party Advisory","VDB Entry"],"url":"https://vuldb.com/?ctiid.252260"},{"source":"cna@vuldb.com","tags":["Permissions Required","Third Party Advisory","VDB Entry"],"url":"https://vuldb.com/?id.252260"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Permissions Required","Third Party Advisory"],"url":"https://jylsec.notion.site/Tenda-w6-has-stack-buffer-overflow-vulnerability-in-formwrlSSIDset-e283b41905934e97b4c65632a0018eba?pvs=4"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Third Party Advisory","VDB Entry"],"url":"https://vuldb.com/?ctiid.252260"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","Third Party Advisory","VDB Entry"],"url":"https://vuldb.com/?id.252260"}],"sourceIdentifier":"cna@vuldb.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-121"}],"source":"cna@vuldb.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-787"}],"source":"nvd@nist.gov","type":"Primary"}]}
|