Files
vuln-nvd/data/2021/CVE-2021-21540.json
T

2 lines
3.1 KiB
JSON

{"affected":[{"affectedData":[{"product":"Integrated Dell Remote Access Controller (iDRAC)","vendor":"Dell","versions":[{"lessThan":"4.40.00.00","status":"affected","version":"unspecified","versionType":"custom"}]}],"source":"security_alert@emc.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:dell:idrac9_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"5E9ED974-1468-4B8B-B82E-5E0340C2601B","versionEndExcluding":"4.40.00.00","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"Dell EMC iDRAC9 versions prior to 4.40.00.00 contain a stack-based overflow vulnerability. A remote authenticated attacker could potentially exploit this vulnerability to overwrite configuration information by injecting arbitrarily large payload."},{"lang":"es","value":"Dell EMC iDRAC9 versiones anteriores a 4.40.00.00, contiene una vulnerabilidad de desbordamiento en la región stack de la memoria. Un atacante autenticado remoto podría explotar potencialmente esta vulnerabilidad para sobrescribir la información de configuración al inyectar una carga útil arbitrariamente grande."}],"id":"CVE-2021-21540","lastModified":"2026-06-17T03:35:44.597","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"SINGLE","availabilityImpact":"PARTIAL","baseScore":5.5,"confidentialityImpact":"NONE","integrityImpact":"PARTIAL","vectorString":"AV:N/AC:L/Au:S/C:N/I:P/A:P","version":"2.0"},"exploitabilityScore":8.0,"impactScore":4.9,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"LOW","baseScore":5.9,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:L","version":"3.1"},"exploitabilityScore":1.6,"impactScore":4.2,"source":"security_alert@emc.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H","version":"3.1"},"exploitabilityScore":2.8,"impactScore":5.2,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2021-04-30T21:15:08.740","references":[{"source":"security_alert@emc.com","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/kbdoc/000185293"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/kbdoc/000185293"}],"sourceIdentifier":"security_alert@emc.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-121"}],"source":"security_alert@emc.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-787"}],"source":"nvd@nist.gov","type":"Primary"}]}