2 lines
2.8 KiB
JSON
2 lines
2.8 KiB
JSON
{"affected":[{"affectedData":[{"product":"Solid-State Drive Professional","vendor":"Intel Corporation","versions":[{"status":"affected","version":"PSF104P, PSF109P"}]}],"source":"secure@intel.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:intel:ssd_pro_6000p_firmware:psf104p:*:*:*:*:*:*:*","matchCriteriaId":"B7D5FC60-C12E-4E56-BA31-4B0544834E67","vulnerable":true},{"criteria":"cpe:2.3:o:intel:ssd_pro_6000p_firmware:psf109p:*:*:*:*:*:*:*","matchCriteriaId":"37C36E2C-A14B-4CF4-B9E7-B33C37D1F3F2","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:intel:ssd_pro_6000p:-:*:*:*:*:*:*:*","matchCriteriaId":"2467F592-716C-4F14-AD78-A63FD5FCA070","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Data corruption vulnerability in firmware in Intel Solid-State Drive Professional PSF104P, PSF109P allows local users to cause a denial of service via unspecified vectors."},{"lang":"es","value":"Una vulnerabilidad de corrupción de datos en el firmware en Intel Solid-State Drive Professional PSF104P, PSF109P permite que usuarios locales provoquen una denegación de servicio mediante vectores sin especificar."}],"id":"CVE-2017-5694","lastModified":"2026-06-17T01:21:03.290","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"LOCAL","authentication":"NONE","availabilityImpact":"COMPLETE","baseScore":4.9,"confidentialityImpact":"NONE","integrityImpact":"NONE","vectorString":"AV:L/AC:L/Au:N/C:N/I:N/A:C","version":"2.0"},"exploitabilityScore":3.9,"impactScore":6.9,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV30":[{"cvssData":{"attackComplexity":"LOW","attackVector":"PHYSICAL","availabilityImpact":"HIGH","baseScore":4.6,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.0"},"exploitabilityScore":0.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2017-08-09T14:29:00.230","references":[{"source":"secure@intel.com","tags":["Vendor Advisory"],"url":"https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00078&languageid=en-fr"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://security-center.intel.com/advisory.aspx?intelid=INTEL-SA-00078&languageid=en-fr"}],"sourceIdentifier":"secure@intel.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"NVD-CWE-noinfo"}],"source":"nvd@nist.gov","type":"Primary"}]}
|