Files
vuln-nvd/data/2026/CVE-2026-4832.json
T

2 lines
4.8 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Easergy MiCOM P14x","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P24x","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to D3A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P341","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to E3F"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P342, P343, P344, P345","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B3F"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P442, P444","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to E3A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P443, P445, P446, P543, P544, P545, P546","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to H6A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P642, P645","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P643","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B3F"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P741, P742, P743","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B2A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P746","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4E or C4E"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P841","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to G6A"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P849","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions prior to B4A"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE-798 Use of Hard-coded Credentials vulnerability exists that could cause unauthorized access to sensitive device information when an unauthenticated attacker is able to interrogate the SNMP port."},{"lang":"es","value":"Existe una vulnerabilidad CWE-798 de Uso de credenciales codificadas de forma rígida que podría causar acceso no autorizado a información sensible del dispositivo cuando un atacante no autenticado es capaz de interrogar el puerto SNMP."}],"id":"CVE-2026-4832","lastModified":"2026-10-26T21:10:00.170","metrics":{"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":6.9,"baseSeverity":"MEDIUM","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-4832","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-04-14T18:15:51.123382Z","version":"2.0.3"}}]},"published":"2026-04-14T16:16:48.167","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-104-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-104-03.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Undergoing Analysis","weaknesses":[{"description":[{"lang":"en","value":"CWE-798"}],"source":"cybersecurity@se.com","type":"Secondary"}]}