2 lines
6.3 KiB
JSON
2 lines
6.3 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Easergy MiCOM C264","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions D6.x"},{"status":"affected","version":"Versions D7.33 and prior"}]},{"defaultStatus":"unaffected","product":"Easergy C5","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 1.1.17 and prior"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P30","vendor":"Schneider Electric","versions":[{"status":"affected","version":"P139 version prior to P139.678.700"},{"status":"affected","version":"P437 version prior to P437.678.700"},{"status":"affected","version":"P439 version prior to P439.678.700"},{"status":"affected","version":"P532 version prior to P532.678.700"},{"status":"affected","version":"P539 version prior to P539.678.700"},{"status":"affected","version":"P631 version prior to P631.678.700"},{"status":"affected","version":"P632 version prior to P632.678.700"},{"status":"affected","version":"P633 version prior to P633.678.700"},{"status":"affected","version":"P634 version prior to P634.678.700"},{"status":"affected","version":"P633 version P633.680.700 only"},{"status":"affected","version":"P634 version P634.680.700 only"},{"status":"affected","version":"P138 version prior to P138.677.700"},{"status":"affected","version":"P436 version prior to P436.677.701"},{"status":"affected","version":"P438 version prior to P438.677.701"},{"status":"affected","version":"P638 version prior to P638.677.700"},{"status":"affected","version":"C434 version prior to C434.679.700"}]},{"defaultStatus":"unaffected","product":"Easergy MiCOM P40","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Series model numbers with Protocol Option bit as G, H or L and all firmware versions"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Automation System Gateway (EPAS-GTW)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 6.4.616.200.100 and prior"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Automation System User Interface (EPAS-UI)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 3.0.3 and prior"}]},{"defaultStatus":"unaffected","product":"EcoStruxure™ Power Operation","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2022 CU6 and prior"},{"status":"affected","version":"Version 2024 CU2 and prior"}]},{"defaultStatus":"unaffected","product":"iPMFLS","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 64.2025.0.13 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ P5 Protection Relay","vendor":"Schneider Electric","versions":[{"status":"affected","version":"V02.502.103 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ P7 Protection and Control Platform","vendor":"Schneider Electric","versions":[{"status":"affected","version":"V02.002.002 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ T300","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 2.9.4 and prior"}]},{"defaultStatus":"unaffected","product":"PowerLogic™ T500","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 11.08.02 and prior"}]},{"defaultStatus":"unaffected","product":"Saitel DP","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 11.06.36 and prior"}]},{"defaultStatus":"unaffected","product":"EasyLogic T150 (formerly Saitel DR)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Version 11.06.30 and prior"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections."},{"lang":"es","value":"Existe una vulnerabilidad CWE-331: Entropía Insuficiente que podría conducir a acceso no autorizado cuando un atacante en la red puede explotar debilidades en las protecciones de gestión de sesión."}],"id":"CVE-2026-4827","lastModified":"2026-10-26T18:10:00.173","metrics":{"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":8.7,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"LOW","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-4827","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2026-05-12T12:39:02.210471Z","version":"2.0.3"}}]},"published":"2026-05-12T13:17:35.510","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-02.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Awaiting Analysis","weaknesses":[{"description":[{"lang":"en","value":"CWE-331"}],"source":"cybersecurity@se.com","type":"Secondary"}]}
|