Files
vuln-nvd/data/2026/CVE-2026-4272.json
T

2 lines
3.3 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Barcode Scanners","vendor":"Honeywell","versions":[{"lessThan":"GK000432BAA","status":"affected","version":"C1 Base(Ingenic x1000)","versionType":"custom"},{"lessThan":"HE000085BAA","status":"affected","version":"D1 Base(Ingenic x1600)","versionType":"custom"},{"lessThan":"BK000763BAA_BK000765BAA_CU000101BAA","status":"affected","version":"A1/B1 Base(IMX25)","versionType":"custom"}]}],"source":"psirt@honeywell.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: from C1 Base(Ingenic x1000) before GK000432BAA, from D1 Base(Ingenic x1600) before HE000085BAA, from A1/B1 Base(IMX25) before BK000763BAA_BK000765BAA_CU000101BAA.\n\nThis vulnerability could allow a remote attacker within Bluetooth range of the scanner's base station has the capability to remotely execute system commands on the host connected to the base station without authentication. This issue has been assigned  CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 and rated with a severity of High. Honeywell strongly recommends that users upgrade to the latest version identified to resolve the vulnerability."},{"lang":"es","value":"La vulnerabilidad 'Missing Authentication for Critical Function' en los escáneres portátiles Honeywell permite el abuso de autenticación. Este problema afecta a los escáneres portátiles: desde C1 Base (Ingenic x1000) anterior a GK000432BAA, desde D1 Base (Ingenic x1600) anterior a HE000085BAA, desde A1/B1 Base (IMX25) anterior a BK000763BAA_BK000765BAA_CU000101BAA.\n\nEsta vulnerabilidad podría permitir que un atacante remoto dentro del alcance de Bluetooth de la estación base del escáner tenga la capacidad de ejecutar comandos del sistema de forma remota en el host conectado a la estación base sin autenticación. A este problema se le ha asignado CVE-2026-4272 https://nvd.nist.gov/vuln/detail/CVE-2026-4272 y se ha calificado con una severidad de Alta. Honeywell recomienda encarecidamente que los usuarios actualicen a la última versión identificada para resolver la vulnerabilidad."}],"id":"CVE-2026-4272","lastModified":"2026-07-24T20:10:00.147","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.1,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N","version":"3.1"},"exploitabilityScore":2.8,"impactScore":5.2,"source":"psirt@honeywell.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-4272","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-04-06T14:00:57.144252Z","version":"2.0.3"}}]},"published":"2026-04-05T22:16:01.697","references":[{"source":"psirt@honeywell.com","url":"https://https://nvd.nist.gov/vuln/detail/CVE-2026-4272"}],"sourceIdentifier":"psirt@honeywell.com","vulnStatus":"Awaiting Analysis","weaknesses":[{"description":[{"lang":"en","value":"CWE-306"}],"source":"psirt@honeywell.com","type":"Secondary"}]}