Files
vuln-nvd/data/2026/CVE-2026-1772.json
T

2 lines
8.8 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"RTU500 series CMU firmware","vendor":"Hitachi Energy","versions":[{"lessThanOrEqual":"12.7.7","status":"affected","version":"12.7.1","versionType":"custom"},{"lessThanOrEqual":"13.5.4","status":"affected","version":"13.5.1","versionType":"custom"},{"lessThanOrEqual":"13.6.2","status":"affected","version":"13.6.1","versionType":"custom"},{"lessThanOrEqual":"13.7.7","status":"affected","version":"13.7.1","versionType":"custom"},{"status":"affected","version":"13.8.1","versionType":"custom"}]}],"source":"cybersecurity@hitachienergy.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"064FFA76-2AD3-425F-B003-4D038C941E7D","versionEndIncluding":"12.7.7","versionStartIncluding":"12.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"AC2DF255-AB45-4CAE-A7BD-0B2A1B5D04D6","versionEndIncluding":"13.5.4","versionStartIncluding":"13.5.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"CB44D4BF-8F0F-4770-A150-A5469A262A5A","versionEndIncluding":"13.6.2","versionStartIncluding":"13.6.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu520_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"432CB425-58CC-47E2-847D-5E3FD31F8EB3","versionEndExcluding":"13.7.8","versionStartIncluding":"13.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu520_firmware:13.8.1:*:*:*:*:*:*:*","matchCriteriaId":"D034F19D-920A-44DE-A886-6021242FF6E3","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:hitachienergy:rtu520:-:*:*:*:*:*:*:*","matchCriteriaId":"11AF93AD-200F-47A6-BA2C-F82165AFB50D","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"50ECC099-2676-45CE-82DA-4A6943452976","versionEndIncluding":"12.7.7","versionStartIncluding":"12.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"3D5D8077-C84A-4821-9F89-76A0F4664927","versionEndIncluding":"13.5.4","versionStartIncluding":"13.5.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"89FAF654-7F2C-4918-B074-6CB685E885D8","versionEndIncluding":"13.6.2","versionStartIncluding":"13.6.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu530_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"0561AA77-CE68-4C93-8611-630FB07B507C","versionEndExcluding":"13.7.8","versionStartIncluding":"13.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu530_firmware:13.8.1:*:*:*:*:*:*:*","matchCriteriaId":"45F698BE-5EDF-46DF-8B1E-96AC8894AA64","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:hitachienergy:rtu530:-:*:*:*:*:*:*:*","matchCriteriaId":"FC6F9377-E6BB-4DEA-9D87-0AF792CBAC57","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"FCFA1FB7-1834-4425-9DDB-0C08140DAD4B","versionEndIncluding":"12.7.7","versionStartIncluding":"12.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"B70918C5-85C2-40B8-8681-921942C41561","versionEndIncluding":"13.5.4","versionStartIncluding":"13.5.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"30F20A11-9ECB-4CC6-88C2-0CC96DFFABE2","versionEndIncluding":"13.6.2","versionStartIncluding":"13.6.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu540_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"199A1127-9B24-46A6-9122-30FD2EF64F32","versionEndExcluding":"13.7.8","versionStartIncluding":"13.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu540_firmware:13.8.1:*:*:*:*:*:*:*","matchCriteriaId":"4D49545F-C765-4579-89C5-01B1EBB45B36","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:hitachienergy:rtu540:-:*:*:*:*:*:*:*","matchCriteriaId":"6EEFDEF0-883D-402B-9CD4-333A145E3C75","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"},{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"EF5BF48F-4BDF-4D38-A836-221066FA6234","versionEndIncluding":"12.7.7","versionStartIncluding":"12.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"C75F1BB5-558A-4292-BA2B-E77D811D5E09","versionEndIncluding":"13.5.4","versionStartIncluding":"13.5.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"4DE20728-0C7A-4388-AA09-AC50C8AD51F9","versionEndIncluding":"13.6.2","versionStartIncluding":"13.6.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu560_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"2CCC0128-9A27-4F4A-B254-C0C31BDCA78B","versionEndExcluding":"13.7.8","versionStartIncluding":"13.7.1","vulnerable":true},{"criteria":"cpe:2.3:o:hitachienergy:rtu560_firmware:13.8.1:*:*:*:*:*:*:*","matchCriteriaId":"B9753BCF-0BE9-4B1A-88B4-0B0DE5F623CE","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:hitachienergy:rtu560:-:*:*:*:*:*:*:*","matchCriteriaId":"495DCBD6-D2D1-4295-81D1-6ACA1B2CA223","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges."},{"lang":"es","value":"Interfaz web de RTU500: Un usuario sin privilegios puede leer información de gestión de usuarios. No se puede acceder a la información a través de la interfaz de usuario web de RTU500, pero requiere herramientas adicionales como utilidades de desarrollo del navegador para acceder a ella sin los privilegios requeridos."}],"id":"CVE-2026-1772","lastModified":"2026-06-17T10:16:29.553","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityImpact":"LOW","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","version":"3.1"},"exploitabilityScore":3.9,"impactScore":1.4,"source":"nvd@nist.gov","type":"Primary"}],"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":5.3,"baseSeverity":"MEDIUM","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@hitachienergy.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-1772","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-02-28T02:18:35.605096Z","version":"2.0.3"}}]},"published":"2026-02-24T14:16:22.180","references":[{"source":"cybersecurity@hitachienergy.com","tags":["Vendor Advisory"],"url":"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000237&LanguageCode=en&DocumentPartId=&Action=Launch"}],"sourceIdentifier":"cybersecurity@hitachienergy.com","vulnStatus":"Analyzed","weaknesses":[{"description":[{"lang":"en","value":"CWE-280"}],"source":"cybersecurity@hitachienergy.com","type":"Secondary"}]}