Files
vuln-nvd/data/2026/CVE-2026-1286.json
T

2 lines
3.8 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"EcoStruxure™ Foxboro DCS","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions prior to CS8.1"}]}],"source":"cybersecurity@se.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:schneider-electric:ecostruxure_foxboro_dcs_control_software:*:*:*:*:*:*:*:*","matchCriteriaId":"8C0BF9B2-1048-4121-BA9F-B1553EC18FF3","versionEndExcluding":"8.1","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file."},{"lang":"es","value":"CWE-502: Existe una vulnerabilidad de deserialización de datos no confiables que podría conducir a la pérdida de confidencialidad, integridad y una posible ejecución remota de código en la estación de trabajo cuando un usuario autenticado como administrador abre un archivo de proyecto malicioso."}],"id":"CVE-2026-1286","lastModified":"2026-06-24T15:36:52.420","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"HIGH","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":0.6,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","availabilityRequirement":"NOT_DEFINED","baseScore":7.0,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"HIGH","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-1286","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2026-03-10T17:54:10.514863Z","version":"2.0.3"}}]},"published":"2026-03-10T18:18:04.917","references":[{"source":"cybersecurity@se.com","tags":["Vendor Advisory","Mitigation"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-03.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Analyzed","weaknesses":[{"description":[{"lang":"en","value":"CWE-502"}],"source":"cybersecurity@se.com","type":"Secondary"}]}