Files
vuln-nvd/data/2026/CVE-2026-1226.json
T

2 lines
3.2 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"EcoStruxure Building Operation Workstation","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All 7.0.x versions prior to 7.0.2"}]},{"defaultStatus":"unaffected","product":"EcoStruxure Building Operation Webstation","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All 6.0.x versions prior to 6.0.4.7000 (CP5)"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE‑94: Improper Control of Generation of Code vulnerability exists that could cause execution of untrusted or unintended code within the application when maliciously crafted design content is processed through a TGML graphics file."},{"lang":"es","value":"CWE?94: Improper Control of Generation of Code existe una vulnerabilidad que podría causar la ejecución de código no confiable o no intencionado dentro de la aplicación cuando contenido de diseño manipulado maliciosamente es procesado a través de un archivo gráfico TGML."}],"id":"CVE-2026-1226","lastModified":"2026-06-17T10:15:21.490","metrics":{"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","availabilityRequirement":"NOT_DEFINED","baseScore":7.0,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"PASSIVE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-1226","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2026-02-11T14:07:20.670514Z","version":"2.0.3"}}]},"published":"2026-02-11T14:16:01.973","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-041-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-041-02.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-94"}],"source":"cybersecurity@se.com","type":"Secondary"}]}