2 lines
3.4 KiB
JSON
2 lines
3.4 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"FLEX I/O EtherNet/IP Adapters","vendor":"Rockwell Automation","versions":[{"status":"affected","version":"2.012","versionType":"custom"}]}],"source":"PSIRT@rockwellautomation.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"An improper authentication security issue exists within the 1794-AENTR adapter's embedded web server. The vulnerability allows an unauthenticated attacker to change the device's web interface password by sending a crafted HTTP GET request to a specific endpoint, without any prior authentication being required. If exploited, this could lead to unauthorized access, account takeover, and loss of the device’s embedded web server’s availability."},{"lang":"es","value":"Un problema de seguridad de autenticación impropia existe dentro del servidor web embebido del adaptador 1794-AENTR. La vulnerabilidad permite a un atacante no autenticado cambiar la contraseña de la interfaz web del dispositivo enviando una solicitud HTTP GET manipulada a un endpoint específico, sin que se requiera ninguna autenticación previa. Si se explota, esto podría llevar a acceso no autorizado, toma de control de cuenta y pérdida de la disponibilidad del servidor web embebido del dispositivo."}],"id":"CVE-2026-0647","lastModified":"2026-10-25T23:10:00.167","metrics":{"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":8.8,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"PSIRT@rockwellautomation.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2026-0647","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2026-06-16T15:23:37.954588Z","version":"2.0.3"}}]},"published":"2026-06-16T15:16:33.687","references":[{"source":"PSIRT@rockwellautomation.com","url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1775.html"}],"sourceIdentifier":"PSIRT@rockwellautomation.com","vulnStatus":"Awaiting Analysis","weaknesses":[{"description":[{"lang":"en","value":"CWE-306"}],"source":"PSIRT@rockwellautomation.com","type":"Secondary"}]}
|