2 lines
3.5 KiB
JSON
2 lines
3.5 KiB
JSON
{"affected":[{"affectedData":[{"product":"Samsung","vendor":"Talos","versions":[{"status":"affected","version":"Samsung SmartThings Hub STH-ETH-250 - Firmware version 0.20.17"}]}],"source":"talos-cna@cisco.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:samsung:sth-eth-250_firmware:0.20.17:*:*:*:*:*:*:*","matchCriteriaId":"69ED63CA-72C3-4337-B1ED-1696DB316B0F","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:samsung:sth-eth-250:-:*:*:*:*:*:*:*","matchCriteriaId":"4B42493E-7140-4A19-B94A-2F6262D0BCDA","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"An exploitable vulnerability exists in the REST parser of video-core's HTTP server of the Samsung SmartThings Hub STH-ETH-250 - Firmware version 0.20.17. The video-core process incorrectly handles pipelined HTTP requests, which allows successive requests to overwrite the previously parsed HTTP method, 'on_url' callback. An attacker can send an HTTP request to trigger this vulnerability."},{"lang":"es","value":"Existe una vulnerabilidad explotable en el analizador REST del servidor HTTP de video-core de Samsung SmartThings Hub STH-ETH-250 en su versión de firmware 0.20.17. El proceso video-core maneja incorrectamente las peticiones HTTP tuneladas, lo que permite que las peticiones sucesivas sobrescriban el método HTTP analizado anteriormente, 'on_url' callback. Un atacante puede enviar una petición HTTP para provocar esta vulnerabilidad."}],"id":"CVE-2018-3907","lastModified":"2026-06-17T01:57:59.890","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":6.4,"confidentialityImpact":"NONE","integrityImpact":"PARTIAL","vectorString":"AV:N/AC:L/Au:N/C:N/I:P/A:P","version":"2.0"},"exploitabilityScore":10.0,"impactScore":4.9,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV30":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.1,"baseSeverity":"CRITICAL","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","version":"3.0"},"exploitabilityScore":3.9,"impactScore":5.2,"source":"talos-cna@cisco.com","type":"Secondary"}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":10.0,"baseSeverity":"CRITICAL","confidentialityImpact":"NONE","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.8,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2018-08-24T00:29:00.210","references":[{"source":"talos-cna@cisco.com","tags":["Exploit","Third Party Advisory"],"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0577"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"],"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2018-0577"}],"sourceIdentifier":"talos-cna@cisco.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-444"}],"source":"nvd@nist.gov","type":"Primary"}]}
|