2 lines
3.1 KiB
JSON
2 lines
3.1 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"MagicINFO 9 Server","vendor":"Samsung Electronics","versions":[{"lessThan":"21.1052","status":"affected","version":"0","versionType":"custom"}]}],"source":"PSIRT@samsung.com"}],"cisaActionDue":"2025-06-12","cisaExploitAdd":"2025-05-22","cisaRequiredAction":"Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.","cisaVulnerabilityName":"Samsung MagicINFO 9 Server Path Traversal Vulnerability","configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:samsung:magicinfo_9_server:*:*:*:*:*:*:*:*","matchCriteriaId":"ADCE2BD5-315B-4F42-8BB9-A419B0C750A7","versionEndExcluding":"21.1052.0","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"Improper limitation of a pathname to a restricted directory vulnerability in Samsung MagicINFO 9 Server version before 21.1052 allows attackers to write arbitrary file as system authority."},{"lang":"es","value":"La vulnerabilidad de limitación incorrecta de una ruta de acceso a un directorio restringido en Samsung MagicINFO 9 Server versión anterior a 21.1052 permite a los atacantes escribir archivos arbitrarios como autoridad del sistema."}],"id":"CVE-2025-4632","lastModified":"2026-06-17T09:33:39.023","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.9,"source":"PSIRT@samsung.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-4632","options":[{"exploitation":"active"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2025-08-20T03:56:08.237171Z","version":"2.0.3"}}]},"published":"2025-05-13T06:15:36.537","references":[{"source":"PSIRT@samsung.com","tags":["Patch","Vendor Advisory"],"url":"https://security.samsungtv.com/securityUpdates#SVP-MAY-2025"},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","tags":["US Government Resource"],"url":"https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2025-4632"}],"sourceIdentifier":"PSIRT@samsung.com","vulnStatus":"Analyzed","weaknesses":[{"description":[{"lang":"en","value":"CWE-22"}],"source":"PSIRT@samsung.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-22"}],"source":"nvd@nist.gov","type":"Primary"}]}
|