2 lines
3.5 KiB
JSON
2 lines
3.5 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"ASCO 5310 Single-Channel Remote Annunciator","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions"}]},{"defaultStatus":"unaffected","product":"ASCO 5350 Eight Channel Remote Annunciator","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure\nof data when network traffic is being sniffed by an attacker."},{"lang":"es","value":"CWE-319: Existe una vulnerabilidad de transmisión de información confidencial en texto plano que podría provocar la exposición de datos cuando un atacante espía el tráfico de la red."}],"id":"CVE-2025-1060","lastModified":"2026-06-17T08:38:18.840","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"cybersecurity@se.com","type":"Secondary"}],"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":8.7,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-1060","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-02-13T15:57:29.829889Z","version":"2.0.3"}}]},"published":"2025-02-13T06:15:22.213","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=sevd-2025-042-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-01.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-319"}],"source":"cybersecurity@se.com","type":"Secondary"}]}
|