{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Enerlin’X IFE interface (LV434001)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions"}]},{"defaultStatus":"unaffected","product":"Enerlin’X eIFE (LV851001)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"All versions"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE-20: Improper Input Validation vulnerability exists that could cause Denial-of-Service of the\nproduct when malicious ICMPV6 packets are sent to the device."},{"lang":"es","value":"CWE-20: Existe una vulnerabilidad de validación de entrada incorrecta que podría provocar la denegación de servicio del producto cuando se envían paquetes ICMPV6 maliciosos al dispositivo."}],"id":"CVE-2025-0815","lastModified":"2026-06-17T08:27:11.463","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"ADJACENT_NETWORK","availabilityImpact":"HIGH","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":2.8,"impactScore":3.6,"source":"cybersecurity@se.com","type":"Secondary"}],"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"ADJACENT","availabilityRequirement":"NOT_DEFINED","baseScore":7.1,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-0815","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-02-13T14:55:14.721767Z","version":"2.0.3"}}]},"published":"2025-02-13T07:15:11.160","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-042-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-04.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-20"}],"source":"cybersecurity@se.com","type":"Secondary"}]}
|