Files
vuln-nvd/data/2025/CVE-2025-0683.json
T

2 lines
4.3 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"CMS8000 Patient Monitor","vendor":"Contec Health","versions":[{"status":"affected","version":"All versions"}]}],"source":"ics-cert@hq.dhs.gov"}],"cveTags":[],"descriptions":[{"lang":"en","value":"In its default configuration, Contec Health CMS8000 Patient Monitor transmits plain-text \npatient data to a hard-coded public IP address when a patient is hooked \nup to the monitor. This could lead to a leakage of confidential patient \ndata to any device with that IP address or an attacker in a \nmachine-in-the-middle scenario."},{"lang":"es","value":"En su configuración predeterminada, el monitor de pacientes Contec Health CMS8000 transmite datos del paciente en texto plano a una dirección IP pública predefinida cuando el paciente se conecta al monitor. Esto podría provocar una filtración de datos confidenciales del paciente a cualquier dispositivo con esa dirección IP o a un atacante en un escenario de \"máquina en el medio\"."}],"id":"CVE-2025-0683","lastModified":"2026-06-17T08:26:57.770","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"HIGH","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":5.9,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":2.2,"impactScore":3.6,"source":"ics-cert@hq.dhs.gov","type":"Secondary"}],"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"PRESENT","attackVector":"NETWORK","availabilityRequirement":"NOT_DEFINED","baseScore":8.2,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"NONE","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"ics-cert@hq.dhs.gov","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-0683","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2025-01-30T19:06:59.525559Z","version":"2.0.3"}}]},"published":"2025-01-30T19:15:14.460","references":[{"source":"ics-cert@hq.dhs.gov","url":"https://www.cisa.gov/news-events/ics-medical-advisories/icsma-25-030-01"},{"source":"ics-cert@hq.dhs.gov","url":"https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://www.bleepingcomputer.com/news/security/backdoor-found-in-two-healthcare-patient-monitors-linked-to-ip-in-china/"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://www.cisa.gov/resources-tools/resources/contec-cms8000-contains-backdoor"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://www.fda.gov/medical-devices/safety-communications/cybersecurity-vulnerabilities-certain-patient-monitors-contec-and-epsimed-fda-safety-communication"}],"sourceIdentifier":"ics-cert@hq.dhs.gov","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-359"}],"source":"ics-cert@hq.dhs.gov","type":"Secondary"}]}