Files
vuln-nvd/data/2025/CVE-2025-0327.json
T

2 lines
4.1 KiB
JSON

{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"EcoStruxure Process Expert","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions 2020R2"},{"status":"affected","version":"Versions 2021 & 2023 (prior to v4.8.0.5715)"}]},{"defaultStatus":"unaffected","product":"EcoStruxure Process Expert for AVEVA System Platform","vendor":"Schneider Electric","versions":[{"status":"affected","version":"Versions 2020R2"},{"status":"affected","version":"Versions 2021 & 2023"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit\ntrail data and the other acting as server managing client request) that could cause a loss of Confidentiality,\nIntegrity and Availability of engineering workstation when an attacker with standard privilege modifies the\nexecutable path of the windows services. To be exploited, services need to be restarted."},{"lang":"es","value":"CWE-269: Existe una vulnerabilidad de administración inadecuada de privilegios para dos servicios (uno de los cuales administra los datos de registro de auditoría y el otro actúa como servidor que administra las solicitudes de los clientes) que podría provocar una pérdida de confidencialidad, integridad y disponibilidad de la estación de trabajo de ingeniería cuando un atacante con privilegios estándar modifica la ruta ejecutable de los servicios de Windows. Para explotarla, es necesario reiniciar los servicios."}],"id":"CVE-2025-0327","lastModified":"2026-06-17T08:26:17.000","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"cybersecurity@se.com","type":"Secondary"}],"cvssMetricV40":[{"cvssData":{"Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","Safety":"NOT_DEFINED","attackComplexity":"LOW","attackRequirements":"NONE","attackVector":"LOCAL","availabilityRequirement":"NOT_DEFINED","baseScore":8.5,"baseSeverity":"HIGH","confidentialityRequirement":"NOT_DEFINED","exploitMaturity":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","privilegesRequired":"LOW","providerUrgency":"NOT_DEFINED","subAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","userInteraction":"NONE","valueDensity":"NOT_DEFINED","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","version":"4.0","vulnAvailabilityImpact":"HIGH","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnerabilityResponseEffort":"NOT_DEFINED"},"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2025-0327","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2025-02-13T14:55:58.362547Z","version":"2.0.3"}}]},"published":"2025-02-13T07:15:10.570","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-042-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-03.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-269"}],"source":"cybersecurity@se.com","type":"Secondary"}]}