{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"5015-AENFTXT","vendor":"Rockwell Automation ","versions":[{"status":"affected","version":"v35"}]}],"source":"PSIRT@rockwellautomation.com"},{"affectedData":[{"cpes":["cpe:2.3:h:rockwellautomation:5015_aenftxt:v35:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"5015_aenftxt","vendor":"rockwellautomation","versions":[{"status":"affected","version":"v35"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:rockwellautomation:5015-aenftxt_firmware:2.011:*:*:*:*:*:*:*","matchCriteriaId":"436F7BB7-A8CA-4E00-9F42-6DDB0D995E09","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:rockwellautomation:5015-aenftxt:-:*:*:*:*:*:*:*","matchCriteriaId":"C699B471-D2E4-4B2F-B0A4-6045B8170354","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nAn input validation vulnerability exists in the Rockwell Automation 5015-AENFTXT that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability. \n\n"},{"lang":"es","value":"Existe una vulnerabilidad de validación de entrada en Rockwell Automation 5015-AENFTXT que hace que el adaptador secundario genere una falla mayor no recuperable (MNRF) cuando se ingresa una entrada maliciosa. Si se explota, la disponibilidad del dispositivo se verá afectada y será necesario reiniciarlo manualmente. Además, se necesita un paquete PTP con formato incorrecto para aprovechar esta vulnerabilidad."}],"id":"CVE-2024-2424","lastModified":"2026-06-17T07:24:30.560","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"NONE","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2424","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2024-04-19T17:11:22.359775Z","version":"2.0.3"}}]},"published":"2024-04-15T22:15:08.657","references":[{"source":"PSIRT@rockwellautomation.com","tags":["Broken Link","Vendor Advisory"],"url":"https://www.rockwellautomation.com/en-us/support/advisory.SD1667.html"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link","Vendor Advisory"],"url":"https://www.rockwellautomation.com/en-us/support/advisory.SD1667.html"}],"sourceIdentifier":"PSIRT@rockwellautomation.com","vulnStatus":"Analyzed","weaknesses":[{"description":[{"lang":"en","value":"CWE-20"}],"source":"PSIRT@rockwellautomation.com","type":"Secondary"},{"description":[{"lang":"en","value":"NVD-CWE-noinfo"}],"source":"nvd@nist.gov","type":"Primary"}]}