Files
vuln-nvd/data/2024/CVE-2024-2050.json
T

2 lines
2.8 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"Easergy T200 (Modbus) Models: T200I, T200E, T200P, T200S, T200H ","vendor":"Schneider Electric","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04MOD-07000104","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Easergy T200 (IEC104) Models: T200I, T200E, T200P, T200S, T200H","vendor":"Schneider Electric ","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04IEC-07000104","versionType":"custom"}]},{"defaultStatus":"unaffected","product":"Easergy T200 (DNP3) Models: T200I, T200E, T200P, T200S, T200H","vendor":"Schneider Electric ","versions":[{"lessThanOrEqual":"prior","status":"affected","version":"SC2-04DNP-07000104","versionType":"custom"}]}],"source":"cybersecurity@se.com"}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nCWE-79: Improper Neutralization of Input During Web Page Generation (‘Cross-site Scripting’)\nvulnerability exists when an attacker injects then executes arbitrary malicious JavaScript code\nwithin the context of the product.\n\n"},{"lang":"es","value":"CWE-79: La vulnerabilidad de neutralización inadecuada de la entrada durante la generación de páginas web (\"cross-site Scripting\") existe cuando un atacante inyecta y luego ejecuta código JavaScript malicioso arbitrario dentro del contexto del producto."}],"id":"CVE-2024-2050","lastModified":"2026-06-17T07:23:37.700","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":8.2,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"LOW","privilegesRequired":"NONE","scope":"CHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:L/A:N","version":"3.1"},"exploitabilityScore":2.8,"impactScore":4.7,"source":"cybersecurity@se.com","type":"Secondary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-2050","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","timestamp":"2024-03-18T16:41:10.356650Z","version":"2.0.3"}}]},"published":"2024-03-18T16:15:08.903","references":[{"source":"cybersecurity@se.com","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-01.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-072-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-072-01.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Deferred","weaknesses":[{"description":[{"lang":"en","value":"CWE-79"}],"source":"cybersecurity@se.com","type":"Secondary"}]}