2 lines
3.1 KiB
JSON
2 lines
3.1 KiB
JSON
{"affected":[{"affectedData":[{"defaultStatus":"unaffected","product":"IGSS Update Service (IGSSupdateservice.exe)","vendor":"Schneider Electric","versions":[{"status":"affected","version":"v16.0.0.23211 and prior"}]}],"source":"cybersecurity@se.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:schneider-electric:interactive_graphical_scada_system:*:*:*:*:*:*:*:*","matchCriteriaId":"93B0387C-D40E-446F-AD55-4214804A0B4D","versionEndIncluding":"16.0.0.23211","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"\nA CWE-306: Missing Authentication for Critical Function vulnerability exists in the IGSS Update\nService that could allow a local attacker to change update source, potentially leading to remote\ncode execution when the attacker force an update containing malicious content.\n\n"},{"lang":"es","value":"Existe una vulnerabilidad \"CWE-306: Autenticación Faltante para Funciones Críticas\" en el servicio de actualización IGSS que podría permitir a un atacante local cambiar la fuente de actualización, lo que podría provocar la ejecución remota de código cuando el atacante fuerce una actualización que contenga contenido malicioso."}],"id":"CVE-2023-4516","lastModified":"2026-06-17T06:38:00.163","metrics":{"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"cybersecurity@se.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2023-4516","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2025-02-26T21:51:14.783705Z","version":"2.0.3"}}]},"published":"2023-09-14T09:15:08.610","references":[{"source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"],"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-255-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-255-01.pdf"}],"sourceIdentifier":"cybersecurity@se.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-306"}],"source":"cybersecurity@se.com","type":"Secondary"}]}
|