{"affected":[{"affectedData":[{"product":"MicroSCADA Pro SYS600","vendor":"ABB","versions":[{"status":"affected","version":"9.3"}]}],"source":"cve@rapid7.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:hitachienergy:microscada_pro_sys600:9.3:*:*:*:*:*:*:*","matchCriteriaId":"0577CAD7-1C5C-40D6-B20B-56F532642583","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:o:microsoft:windows_7:-:sp1:*:*:*:*:*:*","matchCriteriaId":"C2B1C231-DE19-4B8F-A4AA-5B3A65276E46","vulnerable":false},{"criteria":"cpe:2.3:o:microsoft:windows_xp:-:sp3:*:*:*:*:*:*","matchCriteriaId":"C9392D35-7BF5-48E9-879B-BBDE9A9E9AB9","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function."},{"lang":"es","value":"ABB MicroSCADA Pro SYS600 versión 9.3, sufre de una instancia CWE-306: Falta de Autenticación para una Función Crítica."}],"id":"CVE-2019-5620","lastModified":"2026-06-17T02:37:57.347","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"HIGH","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":7.5,"confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","vectorString":"AV:N/AC:L/Au:N/C:P/I:P/A:P","version":"2.0"},"exploitabilityScore":10.0,"impactScore":6.4,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2020-04-29T23:15:13.033","references":[{"source":"cve@rapid7.com","tags":["Third Party Advisory"],"url":"https://www.rapid7.com/db/modules/exploit/windows/scada/abb_wserver_exec"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"],"url":"https://www.rapid7.com/db/modules/exploit/windows/scada/abb_wserver_exec"}],"sourceIdentifier":"cve@rapid7.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-306"}],"source":"cve@rapid7.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-306"}],"source":"nvd@nist.gov","type":"Primary"}]}
|