2 lines
2.7 KiB
JSON
2 lines
2.7 KiB
JSON
{"affected":[{"affectedData":[{"product":"Trend Micro Control Manager","vendor":"Trend Micro","versions":[{"status":"affected","version":"6.0"}]}],"source":"security@trendmicro.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:trendmicro:control_manager:6.0:*:*:*:*:*:*:*","matchCriteriaId":"2F7E3779-69E4-46AB-94E3-4A81E35A5194","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"A external entity processing information disclosure (XXE) vulnerability in Trend Micro Control Manager 6.0 could allow a remote attacker to disclose sensitive information on vulnerable installations."},{"lang":"es","value":"Una vulnerabilidad de revelación de información de procesamiento de entidades externas (XEE) en Trend Micro Control Manager 6.0 podría permitir que un atacante remoto revele información sensible en instalaciones vulnerables."}],"id":"CVE-2018-3600","lastModified":"2026-06-17T01:57:32.060","metrics":{"cvssMetricV2":[{"acInsufInfo":true,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"SINGLE","availabilityImpact":"NONE","baseScore":4.0,"confidentialityImpact":"PARTIAL","integrityImpact":"NONE","vectorString":"AV:N/AC:L/Au:S/C:P/I:N/A:N","version":"2.0"},"exploitabilityScore":8.0,"impactScore":2.9,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV30":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","version":"3.0"},"exploitabilityScore":2.8,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2018-02-09T22:29:00.693","references":[{"source":"security@trendmicro.com","tags":["Patch","Vendor Advisory"],"url":"https://success.trendmicro.com/solution/1119158"},{"source":"security@trendmicro.com","tags":["Third Party Advisory","VDB Entry"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-18-111/"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"],"url":"https://success.trendmicro.com/solution/1119158"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"url":"https://www.zerodayinitiative.com/advisories/ZDI-18-111/"}],"sourceIdentifier":"security@trendmicro.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-611"}],"source":"nvd@nist.gov","type":"Primary"}]}
|