Files
vuln-nvd/data/2017/CVE-2017-2688.json
T

2 lines
3.5 KiB
JSON

{"affected":[{"affectedData":[{"product":"RUGGEDCOM ROX I All versions","vendor":"n/a","versions":[{"status":"affected","version":"RUGGEDCOM ROX I All versions"}]}],"source":"productcert@siemens.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:siemens:ruggedcom_rox_i:*:*:*:*:*:*:*:*","matchCriteriaId":"AE0398E8-031B-4072-A3A5-BF3A2A361AAB","versionEndIncluding":"2.9.0","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"The integrated web server in Siemens RUGGEDCOM ROX I (all versions) at port 10000/TCP could allow remote attackers to perform actions with the privileges of an authenticated user, provided the targeted user has an active session and is induced into clicking on a malicious link or into visiting a malicious website, aka CSRF."},{"lang":"es","value":"El servidor web integrado en Siemens RUGGEDCOM ROX I (todas las versiones) en el puerto 10000/TCP podría permitir a atacantes remotos realizar acciones con los privilegios de un usuario autenticado, siempre que el usuario objetivo tenga una sesión activa e inducido a hacer clic en un enlace malicioso o visitar un sitio web malicioso, también conocido como CSRF."}],"id":"CVE-2017-2688","lastModified":"2026-06-17T01:16:40.230","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"MEDIUM","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"PARTIAL","baseScore":6.8,"confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","vectorString":"AV:N/AC:M/Au:N/C:P/I:P/A:P","version":"2.0"},"exploitabilityScore":8.6,"impactScore":6.4,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":true}],"cvssMetricV30":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","version":"3.0"},"exploitabilityScore":2.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2017-03-29T01:59:01.783","references":[{"source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"],"url":"http://www.securityfocus.com/bid/97170"},{"source":"productcert@siemens.com","url":"http://www.securitytracker.com/id/1038160"},{"source":"productcert@siemens.com","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-087-01"},{"source":"productcert@siemens.com","tags":["Vendor Advisory"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-327980.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"url":"http://www.securityfocus.com/bid/97170"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"http://www.securitytracker.com/id/1038160"},{"source":"af854a3a-2127-422b-91ae-364da2661108","url":"https://ics-cert.us-cert.gov/advisories/ICSA-17-087-01"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-327980.pdf"}],"sourceIdentifier":"productcert@siemens.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-352"}],"source":"productcert@siemens.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-352"}],"source":"nvd@nist.gov","type":"Primary"}]}