Files
vuln-nvd/data/2019/CVE-2019-3984.json

2 lines
2.7 KiB
JSON

{"affected":[{"affectedData":[{"product":"Blink XT2 Sync Module firmware","vendor":"Amazon","versions":[{"status":"affected","version":"prior to 2.13.11"}]}],"source":"vulnreport@tenable.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:amazon:blink_xt2_sync_module_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"D760A965-7A5F-45DA-A530-3E8979A04F57","versionEndExcluding":"2.3.11","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:amazon:blink_xt2_sync_module:-:*:*:*:*:*:*:*","matchCriteriaId":"5AFBC607-8887-4CC7-99D0-60D9C8993EE9","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Blink XT2 Sync Module firmware prior to 2.13.11 allows remote attackers to execute arbitrary commands on the device due to improperly sanitized input when the device retrieves updates scripts from the internet."},{"lang":"es","value":"El módulo de sincronización Blink XT2 versiones del firmware anteriores a la versión 2.13.11, permite a atacantes remotos ejecutar comandos arbitrarios en el dispositivo debido a una entrada saneada inapropiadamente cuando el dispositivo recupera los scripts de actualizaciones de Internet."}],"id":"CVE-2019-3984","lastModified":"2026-06-17T02:35:59.833","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"HIGH","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"COMPLETE","baseScore":10.0,"confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","vectorString":"AV:N/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"exploitabilityScore":10.0,"impactScore":10.0,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":9.8,"baseSeverity":"CRITICAL","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":3.9,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2019-12-31T18:15:11.610","references":[{"source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory"],"url":"https://www.tenable.com/security/research/tra-2019-51"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"],"url":"https://www.tenable.com/security/research/tra-2019-51"}],"sourceIdentifier":"vulnreport@tenable.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-78"}],"source":"nvd@nist.gov","type":"Primary"}]}