Files
vuln-nvd/data/2018/CVE-2018-4836.json

2 lines
3.2 KiB
JSON

{"affected":[{"affectedData":[{"product":"TeleControl Server Basic","vendor":"Siemens AG","versions":[{"status":"affected","version":"All versions < V3.1"}]}],"source":"productcert@siemens.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*","matchCriteriaId":"E31D80D0-A773-45F5-8155-43861100BC48","versionEndExcluding":"3.1","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en TeleControl Server Basic en versiones anteriores a la 3.1. Un atacante autenticado con una cuenta de privilegios bajos en el puerto 8000/tcp de TeleControl Server Basic podría escalar sus privilegios y realizar operaciones administrativas."}],"id":"CVE-2018-4836","lastModified":"2026-06-17T01:59:08.363","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"SINGLE","availabilityImpact":"PARTIAL","baseScore":6.5,"confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","version":"2.0"},"exploitabilityScore":8.0,"impactScore":6.4,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV30":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.0"},"exploitabilityScore":2.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2018-01-25T14:29:00.380","references":[{"source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"],"url":"http://www.securityfocus.com/bid/102897"},{"source":"productcert@siemens.com","tags":["Third Party Advisory","VDB Entry"],"url":"http://www.securityfocus.com/bid/102904"},{"source":"productcert@siemens.com","tags":["Patch","Vendor Advisory"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"url":"http://www.securityfocus.com/bid/102897"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"url":"http://www.securityfocus.com/bid/102904"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"],"url":"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-651454.pdf"}],"sourceIdentifier":"productcert@siemens.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-287"}],"source":"productcert@siemens.com","type":"Secondary"},{"description":[{"lang":"en","value":"NVD-CWE-noinfo"}],"source":"nvd@nist.gov","type":"Primary"}]}