{"affected":[{"affectedData":[{"product":"W20E","vendor":"Tenda","versions":[{"status":"affected","version":"15.11.0.6"}]}],"source":"cna@vuldb.com"},{"affectedData":[{"cpes":["cpe:2.3:o:tenda:w20e_firmware:15.11.0.6:*:*:*:*:*:*:*"],"defaultStatus":"unknown","product":"w20e_firmware","vendor":"tenda","versions":[{"status":"affected","version":"15.11.0.6"}]}],"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:o:tenda:w20e_firmware:15.11.0.6:*:*:*:*:*:*:*","matchCriteriaId":"31C1283D-8DCF-49C0-92FF-34CF842D00BF","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:h:tenda:w20e:-:*:*:*:*:*:*:*","matchCriteriaId":"25F04924-FB40-4330-B9D9-8597E06DF11B","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability was found in Tenda W20E 15.11.0.6. It has been declared as critical. This vulnerability affects the function formSetRemoteWebManage of the file /goform/SetRemoteWebManage. The manipulation of the argument remoteIP leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-260908. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."},{"lang":"es","value":"Se encontró una vulnerabilidad en Tenda W20E 15.11.0.6. Ha sido declarada crítica. Esta vulnerabilidad afecta a la función formSetRemoteWebManage del archivo /goform/SetRemoteWebManage. La manipulación del argumento IP remota conduce a un desbordamiento de búfer en la región stack de la memoria. El ataque se puede iniciar de forma remota. El exploit ha sido divulgado al público y puede utilizarse. El identificador de esta vulnerabilidad es VDB-260908. NOTA: Se contactó primeramente con el proveedor sobre esta divulgación, pero no respondió de ninguna manera."}],"id":"CVE-2024-3874","lastModified":"2026-06-17T07:45:20.417","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"HIGH","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"SINGLE","availabilityImpact":"COMPLETE","baseScore":9.0,"confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","vectorString":"AV:N/AC:L/Au:S/C:C/I:C/A:C","version":"2.0"},"exploitabilityScore":8.0,"impactScore":10.0,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"cna@vuldb.com","type":"Secondary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":2.8,"impactScore":5.9,"source":"cna@vuldb.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":2.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"id":"CVE-2024-3874","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","timestamp":"2024-05-30T19:19:51.539381Z","version":"2.0.3"}}]},"published":"2024-04-16T16:15:09.240","references":[{"source":"cna@vuldb.com","tags":["Broken Link"],"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W20E/formSetRemoteWebManage.md"},{"source":"cna@vuldb.com","tags":["Permissions Required","VDB Entry"],"url":"https://vuldb.com/?ctiid.260908"},{"source":"cna@vuldb.com","tags":["Permissions Required","VDB Entry"],"url":"https://vuldb.com/?id.260908"},{"source":"cna@vuldb.com","tags":["Third Party Advisory","VDB Entry"],"url":"https://vuldb.com/?submit.312816"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Broken Link"],"url":"https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W20E/formSetRemoteWebManage.md"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","VDB Entry"],"url":"https://vuldb.com/?ctiid.260908"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Permissions Required","VDB Entry"],"url":"https://vuldb.com/?id.260908"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory","VDB Entry"],"url":"https://vuldb.com/?submit.312816"}],"sourceIdentifier":"cna@vuldb.com","vulnStatus":"Analyzed","weaknesses":[{"description":[{"lang":"en","value":"CWE-121"}],"source":"cna@vuldb.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-787"}],"source":"nvd@nist.gov","type":"Secondary"}]}