{"affected":[{"affectedData":[{"product":"OMIMSSC (OpenManage Integration for Microsoft System Center)","vendor":"Dell","versions":[{"lessThan":"7.2.1","status":"affected","version":"unspecified","versionType":"custom"}]}],"source":"security_alert@emc.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:dell:emc_omimssc_for_sccm:*:*:*:*:*:*:*:*","matchCriteriaId":"C1F82F95-99C6-44BA-9CB9-2D4ED583B41B","versionEndExcluding":"7.2.1","vulnerable":true},{"criteria":"cpe:2.3:a:dell:emc_omimssc_for_scvmm:*:*:*:*:*:*:*:*","matchCriteriaId":"120662C3-E1C7-4092-876B-50713AD87022","versionEndExcluding":"7.2.1","vulnerable":true}],"negate":false,"operator":"OR"}]}],"cveTags":[],"descriptions":[{"lang":"en","value":"Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to retrieve the system inventory data of the managed device."},{"lang":"es","value":"Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) para SCCM y SCVMM versiones anteriores a 7.2.1, contiene una vulnerabilidad de autenticación inapropiada. Un atacante remoto no autenticado puede explotar esta vulnerabilidad para recuperar los datos de inventario del sistema del dispositivo administrado"}],"id":"CVE-2020-5373","lastModified":"2026-06-17T03:21:22.520","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"NONE","availabilityImpact":"NONE","baseScore":5.0,"confidentialityImpact":"PARTIAL","integrityImpact":"NONE","vectorString":"AV:N/AC:L/Au:N/C:P/I:N/A:N","version":"2.0"},"exploitabilityScore":10.0,"impactScore":2.9,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":6.5,"baseSeverity":"MEDIUM","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"REQUIRED","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":2.8,"impactScore":3.6,"source":"security_alert@emc.com","type":"Secondary"},{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"NONE","baseScore":7.5,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"NONE","privilegesRequired":"NONE","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","version":"3.1"},"exploitabilityScore":3.9,"impactScore":3.6,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2020-07-14T20:15:11.550","references":[{"source":"security_alert@emc.com","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en"}],"sourceIdentifier":"security_alert@emc.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-306"}],"source":"security_alert@emc.com","type":"Secondary"},{"description":[{"lang":"en","value":"CWE-306"}],"source":"nvd@nist.gov","type":"Primary"}]}