{"affected":[{"affectedData":[{"product":"VMware SD-WAN by VeloCloud","vendor":"n/a","versions":[{"status":"affected","version":"VMware SD-WAN by VeloCloud 3.2.x, 3.3.x prior to 3.3.2 p2, 3.4.x prior to 3.4.1"}]}],"source":"security@vmware.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:arista:velocloud_orchestrator:*:*:*:*:*:*:*:*","matchCriteriaId":"5005A3D8-1042-4F8F-9792-444D19AC013E","versionEndExcluding":"3.3.2","versionStartIncluding":"3.1.1","vulnerable":true},{"criteria":"cpe:2.3:a:arista:velocloud_orchestrator:3.3.2:-:*:*:*:*:*:*","matchCriteriaId":"AAB7A4F7-3EA0-4DFD-8A96-9F27D1013896","vulnerable":true},{"criteria":"cpe:2.3:a:arista:velocloud_orchestrator:3.4.0:*:*:*:*:*:*:*","matchCriteriaId":"BEDA3EDD-6AE4-4771-A544-FCA966F7F9FE","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:*","matchCriteriaId":"703AF700-7A70-47E2-BC3A-7FD03B3CA9C1","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"The VeloCloud Orchestrator does not apply correct input validation which allows for blind SQL-injection. A malicious actor with tenant access to Velocloud Orchestrator could enter specially crafted SQL queries and obtain data to which they are not privileged."},{"lang":"es","value":"VeloCloud Orchestrator, no aplica una comprobación de entrada correcta que permite una inyección SQL ciega. Un actor malicioso con acceso tenant a Velocloud Orchestrator podría introducir consultas SQL especialmente diseñadas y obtener datos que no son privilegiados"}],"id":"CVE-2020-3973","lastModified":"2026-07-28T14:54:01.770","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"MEDIUM","cvssData":{"accessComplexity":"LOW","accessVector":"NETWORK","authentication":"SINGLE","availabilityImpact":"PARTIAL","baseScore":6.5,"confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","vectorString":"AV:N/AC:L/Au:S/C:P/I:P/A:P","version":"2.0"},"exploitabilityScore":8.0,"impactScore":6.4,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"NETWORK","availabilityImpact":"HIGH","baseScore":8.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":2.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2020-07-08T14:15:10.413","references":[{"source":"security@vmware.com","tags":["Vendor Advisory"],"url":"https://www.vmware.com/security/advisories/VMSA-2020-0016.html"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"],"url":"https://www.vmware.com/security/advisories/VMSA-2020-0016.html"}],"sourceIdentifier":"security@vmware.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-89"}],"source":"nvd@nist.gov","type":"Primary"}]}