{"affected":[{"affectedData":[{"product":"Druva inSync Windows Client","vendor":"n/a","versions":[{"status":"affected","version":"6.5.0"}]}],"source":"vulnreport@tenable.com"}],"configurations":[{"nodes":[{"cpeMatch":[{"criteria":"cpe:2.3:a:druva:insync_client:6.5.0:*:*:*:*:*:*:*","matchCriteriaId":"45B8BDDE-9F3D-4040-9228-767451238088","vulnerable":true}],"negate":false,"operator":"OR"},{"cpeMatch":[{"criteria":"cpe:2.3:o:microsoft:windows:-:*:*:*:*:*:*:*","matchCriteriaId":"A2572D17-1DE6-457B-99CC-64AFD54487EA","vulnerable":false}],"negate":false,"operator":"OR"}],"operator":"AND"}],"cveTags":[],"descriptions":[{"lang":"en","value":"Improper neutralization of special elements used in an OS command in Druva inSync Windows Client 6.5.0 allows a local, unauthenticated attacker to execute arbitrary operating system commands with SYSTEM privileges."},{"lang":"es","value":"La neutralización inapropiada de elementos especiales utilizados en un comando del Sistema Operativo en Druva inSync Windows Client versión 6.5.0, permite a un atacante no autenticado local ejecutar comandos arbitrarios del sistema operativo con privilegios SYSTEM."}],"id":"CVE-2019-3999","lastModified":"2026-06-17T02:36:01.260","metrics":{"cvssMetricV2":[{"acInsufInfo":false,"baseSeverity":"HIGH","cvssData":{"accessComplexity":"LOW","accessVector":"LOCAL","authentication":"NONE","availabilityImpact":"COMPLETE","baseScore":7.2,"confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","vectorString":"AV:L/AC:L/Au:N/C:C/I:C/A:C","version":"2.0"},"exploitabilityScore":3.9,"impactScore":10.0,"obtainAllPrivilege":false,"obtainOtherPrivilege":false,"obtainUserPrivilege":false,"source":"nvd@nist.gov","type":"Primary","userInteractionRequired":false}],"cvssMetricV31":[{"cvssData":{"attackComplexity":"LOW","attackVector":"LOCAL","availabilityImpact":"HIGH","baseScore":7.8,"baseSeverity":"HIGH","confidentialityImpact":"HIGH","integrityImpact":"HIGH","privilegesRequired":"LOW","scope":"UNCHANGED","userInteraction":"NONE","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","version":"3.1"},"exploitabilityScore":1.8,"impactScore":5.9,"source":"nvd@nist.gov","type":"Primary"}]},"published":"2020-02-25T19:15:11.693","references":[{"source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory","VDB Entry"],"url":"http://packetstormsecurity.com/files/157493/Druva-inSync-Windows-Client-6.5.2-Privilege-Escalation.html"},{"source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory","VDB Entry"],"url":"http://packetstormsecurity.com/files/157680/Druva-inSync-inSyncCPHwnet64.exe-RPC-Type-5-Privilege-Escalation.html"},{"source":"vulnreport@tenable.com","tags":["Exploit","Third Party Advisory"],"url":"https://www.tenable.com/security/research/tra-2020-12"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory","VDB Entry"],"url":"http://packetstormsecurity.com/files/157493/Druva-inSync-Windows-Client-6.5.2-Privilege-Escalation.html"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory","VDB Entry"],"url":"http://packetstormsecurity.com/files/157680/Druva-inSync-inSyncCPHwnet64.exe-RPC-Type-5-Privilege-Escalation.html"},{"source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"],"url":"https://www.tenable.com/security/research/tra-2020-12"}],"sourceIdentifier":"vulnreport@tenable.com","vulnStatus":"Modified","weaknesses":[{"description":[{"lang":"en","value":"CWE-78"}],"source":"nvd@nist.gov","type":"Primary"}]}