"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-9395",
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"state": "PUBLISHED",
"assignerShortName": "VulDB",
"dateReserved": "2026-05-24T06:18:55.457Z",
"datePublished": "2026-05-24T20:00:11.355Z",
"dateUpdated": "2026-05-26T13:20:38.881Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB",
"dateUpdated": "2026-05-24T20:00:11.355Z"
},
"title": "Besen BS20 EV Charging Station BLE/UDP insufficiently protected credentials",
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-522",
"lang": "en",
"description": "Insufficiently Protected Credentials"
}
]
}
],
"affected": [
{
"vendor": "Besen",
"product": "BS20 EV Charging Station",
"versions": [
{
"version": "20260426",
"status": "affected"
}
],
"cpes": [
"cpe:2.3:a:besen:bs20_ev_charging_station:*:*:*:*:*:*:*:*"
],
"modules": [
"BLE/UDP"
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426. Affected is an unknown function of the component BLE/UDP. The manipulation leads to insufficiently protected credentials. The attack needs to be initiated within the local network. The original disclosure mentions, that \"[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026.\""
}
],
"metrics": [
{
"cvssV4_0": {
"version": "4.0",
"baseScore": 5.1,
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P",
"baseSeverity": "MEDIUM"
}
},
{
"cvssV3_1": {
"version": "3.1",
"baseScore": 3.5,
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"baseSeverity": "LOW"
}
},
{
"cvssV3_0": {
"version": "3.0",
"baseScore": 3.5,
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N/E:P/RL:X/RC:R",
"baseSeverity": "LOW"
}
},
{
"cvssV2_0": {
"version": "2.0",
"baseScore": 2.7,
"vectorString": "AV:A/AC:L/Au:S/C:P/I:N/A:N/E:POC/RL:ND/RC:UR"
}
}
],
"timeline": [
{
"time": "2026-05-24T00:00:00.000Z",
"lang": "en",
"value": "Advisory disclosed"
},
{
"time": "2026-05-24T02:00:00.000Z",
"lang": "en",
"value": "VulDB entry created"
},
{
"time": "2026-05-24T08:24:12.000Z",
"lang": "en",
"value": "VulDB entry last update"
}
],
"credits": [
{
"lang": "en",
"value": "carfeii (VulDB User)",
"type": "reporter"
},
{
"lang": "en",
"value": "VulDB CNA Team",
"type": "coordinator"
}
],
"references": [
{
"url": "https://vuldb.com/vuln/365376",
"name": "VDB-365376 | Besen BS20 EV Charging Station BLE/UDP insufficiently protected credentials",
"tags": [
"vdb-entry"
]
},
{
"url": "https://vuldb.com/vuln/365376/cti",
"name": "VDB-365376 | CTI Indicators (IOB, IOC, TTP)",
"tags": [
"signature",
"permissions-required"
]
},
{
"url": "https://vuldb.com/submit/813572",
"name": "Submit #813572 | Besen EV Charging Station BS20 EV Charger Insufficiently Protected Credentials",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://github.com/carfeii/besen#finding-2-cleartext-credential-exposure-via-ble-and-udp-in-besen-home-ev-charging-station",
"tags": [
"related"
]
}
]
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-05-26T13:20:04.970912Z",
"id": "CVE-2026-9395",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-05-26T13:20:38.881Z"
}
}
]
}
}